1995 Standard Specifications Book Last Update (04/22/2002)
Click here to return to Index Page
DIVISION VI - LIGHTING AND SIGNING
Table Of Contents
ITEM NO. - TITLE AND REQUIREMENTS
610 - ROADWAY ILLUMINATION
ASSEMBLIES
SPECIFICATION REQUIREMENTS
1) Locations and types of roadway illumination assemblies must be shown on the plans.
2) Foundations for roadway illumination assemblies will be constructed to the details
shown on
the plans and will be paid for under Item 656.
3) The following Statewide Standard Details Sheets are required for the fabrication and
installation of
roadway illumination assemblies:
- ED(1)-00(M) Electrical Details - Conduit
- ED(2)-00(M) Electrical Details -
Conductors
- RID(1)-98(M) Roadway Illumination Details
- RID(2)-98(M) Roadway Illumination Details
- RID(3)-98(M) Roadway Illumination Details
- RID(4)-98(M) Roadway Illumination Details
OPTIONAL REQUIREMENTS
None
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Roadway Illumination Assemblies (Type
Specified)" |
EA |
REFERENCE ITEMS
(441, 442, 445, 447, 449, 616, 620, 656)
Go to Top
611 - REMOVING ROADWAY
ILLUMINATION ASSEMBLIES
SPECIFICATION REQUIREMENTS
1) Locations and types of roadway illumination assemblies to be removed must be shown on
the plans.
2) The following Statewide Standard Details Sheets are required for removing roadway
illumination assemblies:
- ED(1)-00(M) Electrical Details - Conduit
- ED(2)-00(M)
Electrical Details - Conductors, Ground Boxes
- RID(1)-98(M) Roadway Illumination Details
- RID(2)-98(M) Roadway Illumination Details
OPTIONAL REQUIREMENTS
None
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Removing Roadway Illumination Assemblies
(Type Specified)" |
EA |
REFERENCE ITEMS
(624)
Go to Top
612 - RELOCATING ROADWAY
ILLUMINATION ASSEMBLIES
SPECIFICATION REQUIREMENTS
1) Locations and types of roadway illumination assemblies to be relocated must be shown
on the plans.
2) The roadway illumination assemblies will be reinstalled at locations shown on
the plans.
3) The new foundations for the relocated roadway illumination assemblies will be
constructed
to the details shown on the plans and will be paid for under Item
656.
4) The following Statewide Standard Details Sheets are required for the details for the
installation
of relocating roadway illumination assemblies:
- ED(1)-00(M) Electrical Details - Conduit
- ED(2)-00(M) Electrical Details - Conductors, Ground Boxes
- RID(1)-98(M) Roadway Illumination Details
- RID(2)-98(M) Roadway Illumination Details
- RID(3)-98(M) Roadway Illumination Details
- RID(4)-98(M) Roadway Illumination Details
OPTIONAL REQUIREMENTS
None
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Relocating Roadway Illumination Assemblies
(Type Specified)" |
EA |
REFERENCE ITEMS
(445, 610, 616, 618, 620, 622, 656)
Go to Top
613 - HIGH MAST ILLUMINATION
POLES
SPECIFICATION REQUIREMENTS
1) The locations, design wind speed and heights of the high mast illumination poles must
be
shown on the plans.
2) Foundations for the high mast illumination poles will be constructed to the details
shown
on the plans and will be paid for under Item 416.
3) All pole shaft sections will be match-marked as shown on the plans.
4) If desired, details for riprap around pole foundations will be shown on the plans.
5) For optional pole designs, the top pole diameter and the top attachment plate will be
as
shown on the plans and the bottom of the pole will be compatible
with the foundation
details shown on plans.
6) The following Statewide Standard Details Sheets are required for the fabrication and
installation of high mast illumination poles:
- HMIP(1)-98(M) High Mast Illumination Poles
and HMIP(2)-98(M)
- HMIF(1)-98(M) High Mast Illumination Pole Foundations
and HMIF(2)-98(M)
OPTIONAL REQUIREMENTS
None
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"High Mast Illumination Poles (Height
Specified) |
|
|
(Design Wind Speed Specified)" |
EA |
REFERENCE ITEMS
(416, 441, 442, 445, 449, 618)
Go to Top
614 - HIGH MAST ILLUMINATION
ASSEMBLIES
SPECIFICATION REQUIREMENTS
1) Locations and types of high mast illumination assemblies must be shown on the
plans.
2) The airway-highway clearance must be approved by the FAA if located near an airport and
the
high mast illumination assemblies protrude into
the navigable air space. This should be handled
in the early stages of plan development.
3) The following Statewide Standard Details Sheets are required for the fabrication and
installation
of high mast illumination assemblies:
- HMID(1-10)-96(M) High Mast Illumination Details
(10 sheets)
OPTIONAL REQUIREMENTS
None
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"High Mast Illumination Assemblies (Type
Specified)" |
EA |
REFERENCE ITEMS
( 441, 445, 616)
Go to Top
616 - PERFORMANCE TESTING OF
LIGHTING SYSTEMS
SPECIFICATION REQUIREMENTS
1) Performance testing is required for roadway lighting fixtures, high mast lighting
fixtures,
and sign lighting fixtures.
OPTIONAL REQUIREMENTS
None
PAYMENT AND MEASUREMENT
Subsidiary to the various bid items in the contract.
REFERENCE ITEMS
(618, 620, 622)
Go to Top
618 - CONDUIT
SPECIFICATION REQUIREMENTS
1) Types, sizes and length of conduits must be shown on the plans.
2) The locations for the placement of conduits will be shown on the plans or as approved by
the Engineer.
3) This is a plans quantity measurement Item.
4) The following Statewide Standard Details Sheets are required for the placement of
conduit:
- ED(1)-00M) Electrical Details - Conduit
- ED(2)-00(M) Electrical Details - Conductors, Ground Boxes
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Conduit (Type
and Size
Specified)" |
M |
REFERENCE ITEMS
(400, 476)
Go to Top
620 - ELECTRICAL CONDUCTORS
SPECIFICATION REQUIREMENTS
1) The size, type and length of electrical conductors must be shown on the plans.
2) This is a plans quantity measurement Item.
3) The following Statewide Standard Details Sheets are required for the placement of
electrical conductors:
- ED(1)-00(M) Electrical Details - Conduit
- ED(2)-00(M) Electrical Details - Conductors, Ground Boxes
OPTIONAL REQUIREMENTS
None
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Electrical Conductors (Size
Specified) (Type Specified)" |
M |
REFERENCE ITEMS
None
Go to Top
622 - DUCT CABLE
SPECIFICATION REQUIREMENTS
1) The types, sizes and length of duct cable must be shown on the plans.
2) If the duct cable is placed by open trench methods, the location and depth of trench
must
be shown on the plans.
3) This is a plans quantity measurement Item.
4) The following Statewide Standard Details Sheets are required for the placement of duct
cable:
- ED(1)-00(M) Electrical Details - Conduit
- ED(2)-00(M) Electrical Details - Conductors, Ground Boxes
- ED(10)-00(M) Electrical Details - Duct Cable
OPTIONAL REQUIREMENTS
None
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Duct Cable (Type
and Size
Specified)" |
M |
REFERENCE ITEMS
(400, 620)
Go to Top
624 - GROUND BOXES
SPECIFICATION REQUIREMENTS
1) The types and sizes of the ground boxes complete with lids must be shown on
the plans.
2) Locations of the ground boxes must be shown on the plans.
3) A concrete apron can be provided when shown on the plans.
4) The following Statewide Standard Details Sheets are required for design details and
installation
of ground boxes:
- ED(1)-00(M)
Electrical Details - Conduit
- ED(2)-00(M)
Electrical Details - Conductors, Ground Boxes
OPTIONAL REQUIREMENTS
None
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Ground Boxes (Type Specified) (Size
Specified)" |
EA |
REFERENCE ITEMS
(421, 440)
Go to Top
625 - ZINC-COATED STEEL WIRE
STRAND
SPECIFICATION REQUIREMENTS
1) The diameter sizes of the zinc-coated steel wire strands must be shown on the
plans.
2) Installation of the zinc-coated steel wire strands must be shown on the plans.
OPTIONAL REQUIREMENTS
None
PAYMENT AND MEASUREMENT
Subsidiary to the various bid items in the contract.
*If special provision 625-001
is used, the following payment and measurement apply.
|
PAYMENT DESCRIPTION |
UNITS |
*1) |
"Zinc-Coated Steel Wire Strand (Size
Specified)" |
M |
REFERENCE ITEMS
None
Go to Top
627 - TREATED TIMBER POLES
SPECIFICATION REQUIREMENTS
1) The types and lengths of the treated timber poles must be shown on the plans.
2) The treated timber poles will be installed at locations shown on the plans or
as directed
by the Engineer.
OPTIONAL REQUIREMENTS
None
PAYMENT AND MEASUREMENT
Subsidiary to the various bid items in the contract.
REFERENCE ITEMS
None
Go to Top
628 - ELECTRICAL SERVICES
SPECIFICATION REQUIREMENTS
1) The types of electrical services must be shown on the plans.
2) The following Statewide Standard Detail Sheets are required for the installation of
electrical services:
- ED(1)-00(M)
Electrical Details - Conduit
- ED(2)-00(M)
Electrical Details - Conductors, Ground Boxes
3) The following Statewide Standard Details
Sheets are available for the installation of electrical services
of the types shown on the plans:
- ED(3-10)-00(M)
Electrical Details
OPTIONAL REQUIREMENTS
None
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Electrical Services (Type Specified)" |
EA |
REFERENCE ITEMS
(441, 445, 449, 618, 620, 627, 656)
Go to Top
629 - REMOVING SERVICE POLES
SPECIFICATION REQUIREMENTS
1) The locations of the service poles to be removed must be shown on the plans.
2) All splices, where permitted or required, will be made in ground boxes or as
shown on the plans.
3) Any materials removed and designated for reuse or retention by the State must be
shown
on the plans.
OPTIONAL REQUIREMENTS
None
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Removing Service Poles" |
EA |
REFERENCE ITEMS
None
Go to Top
634 - PLYWOOD SIGNS (TYPE A)
SPECIFICATION REQUIREMENTS
1) The location and details of the fabrication and erection of the plywood signs must be
shown on the plans.
2) The types and sizes of the plywood signs must be shown on the plans.
3) Sign faces will be of the colors and types shown on the plans.
4) Sign messages will be of the sizes, types and colors shown on the plans.
5) The contractor's working drawings for signs requiring the use of a removable legend
will
conform to the details shown on the plans.
6) Sign blanks will be of the sizes and shapes shown on the plans.
7) This is a plans quantity measurement Item.
OPTIONAL REQUIREMENTS
None
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Plywood Signs (Type A) (Type
Specified) (Size Specified)" |
M2 |
REFERENCE ITEMS
(636, 643)
Go to Top
636 - ALUMINUM SIGNS (TYPE A)
SPECIFICATION REQUIREMENTS
1) The location and details of the fabrication and erection of the aluminum signs must be
shown on the plans.
2) The types and sizes of the aluminum signs must be shown on the plans.
3) Sign blanks substrates will be of the sizes and thickness shown on the plans.
4) Sign faces will be of the colors and types shown on the plans.
5) Sign messages will be of the sizes, types and colors shown on the plans.
6) This is a plans quantity measurement Item.
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Aluminum Signs (Type
A) (Type and Size Specified)" |
M2 |
REFERENCE ITEMS
(643)
Go to Top
|