DIVISION IV - STRUCTURES
Table Of Contents
ITEM NO. - TITLE AND REQUIREMENTS
400 - EXCAVATION AND BACKFILL FOR STRUCTURES
SPECIFICATION REQUIREMENTS
1) Excavation for structures shall conform to the lines and grades shown on the plans or as
directed by the Engineer.
2) For trench and/or negative projecting conditions for concrete pipe culverts, excavation
diagrams will be shown on the plans.
3) When existing pavement and base are to be cut and restored, the type and thickness of the
replaced materials will be as shown on the plans.
4) Bedding will be in accordance with Class C bedding, unless otherwise shown on the plans.
5) When cement stabilized backfill is required, the excavation shall be backfilled with cement
stabilized backfill to the elevations shown on the plans and excavation diagram.
6) The type of aggregate used for cement stabilized backfill will be as shown on the plans or as
approved by the Engineer.
7) Quantities for structural excavation of culvert widening (extensions) greater than 5 meters
and for all other types of structures not listed in Article 400.7. will be shown on the plans.
8) This is a plans quantity measurement Item.
OPTIONAL REQUIREMENTS
1) Protection methods for excavations greater than 1.5 meters in depth shall be measured
and paid for as required under Item 402, "Trench Excavation Protection" or Item
403, "Temporary Special Shoring"
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Structural Excavation" |
M3 |
2) |
"Structural Excavation (Bridge)" |
M3 |
3) |
"Structural Excavation (Culvert, Small)" |
M3 |
4) |
"Structural Excavation (Culvert, Large)" |
M3 |
5) |
"Structural Excavation (Trench)" |
M3 |
6) |
"Structural Excavation (Riprap)" |
M3 |
7) |
"Cement Stabilized Backfill" |
M3 |
8) |
"Cut and Restore Pavement" |
M3 |
REFERENCE ITEMS
(132, 420, 421, 524)
Go to Top
402 - TRENCH EXCAVATION PROTECTION
SPECIFICATION REQUIREMENTS
1) This Item governs for the excavation protection required for trenches in excess of 1.5 meters.
2) Note that a single wall excavation is a trench, if forms or a structure is placed in the excavation
less than 5 meters from the excavated wall.
3) Construction methods are as required by OSHA's Standards and Interpretations.
OPTIONAL REQUIREMENTS
None
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Trench Excavation Protection" |
M |
REFERENCE ITEMS
None
Go to Top
403 - TEMPORARY SPECIAL SHORING
SPECIFICATION REQUIREMENTS
1) The Contractor will submit details and design calculations to the Engineer for review
and approval.
2) The plans will show the top of shoring and the minimum protection grade line.
OPTIONAL REQUIREMENTS
None
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Temporary Special Shoring" |
M2 |
REFERENCE ITEMS
None
Go to Top
404 - DRIVING PILING
SPECIFICATION REQUIREMENTS
1) Embankment at bridge ends will be completed prior to driving of piling.
2) Test piling locations must be shown on the plans.
OPTIONAL REQUIREMENTS
None
PAYMENT AND MEASUREMENT
Subsidiary to the various bid items in the contract.
REFERENCE ITEMS
None
Go to Top
405 - FOUNDATION TEST LOAD
SPECIFICATION REQUIREMENTS
1) Piling or drilled shafts to be test loaded will be specified on the plans.
2) The department will furnish jacking equipment, beams and displacement indicators, unless
otherwise specified.
OPTIONAL REQUIREMENTS
1) The driving of anchor and test piling shall be in accordance with Item 404, "Driving Piling"
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Foundation Test Load" |
EA |
REFERENCE ITEMS
None
Go to Top
406 - TIMBER PILING
SPECIFICATION REQUIREMENTS
1) Size, type, length and details of the timber piling must be shown on the plans.
2) Splices shall be made in accordance with the details shown on the plans.
OPTIONAL REQUIREMENTS
1) When treated timber piling is used, it shall be in accordance with Item 492.
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Treated Timber Piling" |
M |
2) |
"Untreated Timber Piling" |
M |
REFERENCE ITEMS
(404)
Go to Top
407 - STEEL PILING
SPECIFICATION REQUIREMENTS
1) Type, mass, locations and lengths of steel piling must be shown on the plans.
2) The type, section modulus and minimum thickness of steel sheet piling must be specified
the on the plans.
3) Need paint note in the General Notes and Specification Data if any painting will be done
on exposed pile is other than that called for in the Standard Specification.
OPTIONAL REQUIREMENTS
1) When test loading is required, it shall be in accordance with Item 405.
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Steel H-Piling (Size and
Weight Specified)" |
M |
2) |
"Steel H-Test Piling (Size and
Weight Specified)" |
M |
3) |
"Sheet Piling (Type)" |
M2 |
REFERENCE ITEMS
(404, 441, 442, 446, 448)
Go to Top
409 - PRESTRESSED CONCRETE PILING
SPECIFICATION REQUIREMENTS
1) Size, locations and lengths must be shown on the plans.
2) When test piling is required, locations must be shown on the plans.
OPTIONAL REQUIREMENTS
1) When test loading is required, it shall be in accordance with Item 405.
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Prestressed Concrete Piling (Size)" |
M |
2) |
"Prestressed Concrete Test Piling (Size)" |
M |
REFERENCE ITEMS
(404, 420, 421, 424, 425, 426, 440, 5381)
Go to Top
416 - DRILLED SHAFT FOUNDATIONS
SPECIFICATION REQUIREMENTS
1) Details, sizes and dimensions must be shown on the plans.
2) Plans should indicate the expected depths and elevations where satisfactory bearing materials
will be encountered.
3) Size and shape of bell footings must be shown on the plans, when required.
4) Horizontal steel bands, when required, will be placed and welded as shown on the plans.
5) Unless otherwise shown on the plans, drilled shafts may be constructed by the "Slurry
Displacement Method".
6) The quantity of concrete for bell footings must be shown on the plans and is a plans quantity
measurement Item.
OPTIONAL REQUIREMENTS
1) When test loading is required, it shall be in accordance with Item 405.
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Drilled Shaft (Size)" |
M |
2) |
"Drilled Shaft (Nonreinforced) (Size)" |
M |
3) |
"Bell Footings" |
M3 |
REFERENCE ITEMS
(420, 421, 440, 448, 520, 522, 524)
Go to Top
420 - CONCRETE STRUCTURES
SPECIFICATION REQUIREMENTS
1) Class of concrete must be shown on the plans for each type of structure or unit if not specified
by pertinent governing specifications.
2) Weep holes and drains will be installed and constructed as shown on the plans.
3) Expansion joint material will be as shown on the plans.
4) Placing sequence will be as shown on the plans for placing concrete in concrete arches.
5) This is a plans quantity measurement Item.
OPTIONAL REQUIREMENTS
1) Unless otherwise specified, concrete for foundation seals shall be in accordance with Item 400.
2) When required, falsework piling shall be driven to the required resistance determined
by applicable formula shown in Item 404.
3) When required, bearing areas for steel units shall be constructed in accordance with Item 441.
4) When required, welding shall conform to the requirements of Item 448.
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Class ___ Concrete
(Type Structure Specified)" |
M, M2, M3, EA |
REFERENCE ITEMS
(421, 426, 427, 433, 435, 437, 438, 440, 520, 522, 524, 526, 5381)
Go to Top
421 - PORTLAND CEMENT CONCRETE
SPECIFICATION REQUIREMENTS
None
OPTIONAL REQUIREMENTS
None
PAYMENT AND MEASUREMENT
Subsidiary to the various bid items in the contract.
REFERENCE ITEMS
(360, 420, 426, 427, 431, 437, 520, 522, 524)
Go to Top
422 - REINFORCED CONCRETE SLAB
SPECIFICATION REQUIREMENTS
1) The design and details of the reinforced concrete slab will be as shown on the plans.
2) Unless otherwise noted, the Contractor has the option of using conventional forms, permanent
metal deck forms (PMDF) or prestressed precast concrete panels (PCP) for forms for
constructing a cast-in-place slab.
3) Reinforcing steel to be epoxy coated will be shown on the plans when required.
4) This is a plans quantity measurement Item.
OPTIONAL REQUIREMENTS
1) When prestressed precast concrete panels (PCP) are allowed, they shall be in accordance with Item 424.
2) When prestressed units are used, they shall be in accordance with Item 426.
3) When extending structures are required, they shall be in accordance with Item 430.
4) When permanent metal deck forms (PMDF) are allowed, they shall be in accordance with Item 443.
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Reinforced Concrete Slab" |
M2 |
REFERENCE ITEMS
(420, 421, 427, 437, 440, 520, 522, 524, 526)
Go to Top
423 - RETAINING WALL
SPECIFICATION REQUIREMENTS
1) Type B backfill will be used, unless otherwise shown on the plans.
2) When cement stabilized backfill is used, special drainage provisions will be provided on the plans.
3) This is a plans quantity measurement Item.
OPTIONAL REQUIREMENTS
1) When precast units are allowed, they will be in accordance with Items 424, 425 and 426.
2) When galvanizing is required, it will be in accordance with Item 445.
3) When waterproofing is required, it will be in accordance with Item 458.
4) When pipe underdrains are required, they will be in accordance with Item 556.
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Retaining Wall (Type and/or Special Surface Finish
Specified)" |
M2 |
REFERENCE ITEMS
(110, 132, 400, 420, 421, 440, 520, 524, 526)
Go to Top
424 - PRECAST CONCRETE STRUCTURES (FABRICATION)
SPECIFICATION REQUIREMENTS
1) Shop drawings will be required for prestressed members.
OPTIONAL REQUIREMENTS
None
PAYMENT AND MEASUREMENT
Subsidiary to the various bid items in the contract.
REFERENCE ITEMS
None
Go to Top
425 - PRESTRESSED CONCRETE STRUCTURAL MEMBERS
SPECIFICATION REQUIREMENTS
1) Dimensions for panel bedding strips will be shown on the plans.
2) This is a plans quantity measurement Item.
OPTIONAL REQUIREMENTS
1) When PCP's are permitted, they will be in accordance with Item 433.
2) When structural steel is required, they will be in accordance with Item 442.
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Prestress Concrete (Type and/or Size Specified)" |
M, M2, EA |
REFERENCE ITEMS
(421, 424, 426, 427, 435, 440, 5381)
Go to Top
426 - PRESTRESSING
SPECIFICATION REQUIREMENTS
1) Class of concrete will be shown on the plans.
2) Total tension will be shown on the plans for pretensioning.
3) Post-tensioned tendons will be grouted or coated, as required by the plans.
4) Post-tension, "Partial Tensioning Strength", will be specified on the plans.
5) This is a plans quantity measurement Item.
OPTIONAL REQUIREMENTS
1) When precast units are allowed or required, they will be in accordance with Item 424.
2) When joint sealants and fillers are allowed or required, they will be in accordance with Item 433.
3) When structural steel is allowed or required, it will be in accordance with Item 442.
|
PAYMENT DESCRIPTION |
UNITS |
1) |
"Prestressing (Grouted)" |
KNM |
2) |
"Prestressing (Ungrouted)" |
KNM |
REFERENCE ITEMS
(409, 420, 421, 425, 435, 440, 524)
Go to Top
|