Tabulation of Bids for Project F 2024(123)
Use this interactive Tableau dashboard to display bidding information on projects let through statewide and local district letting for the past 24 months.
The Electronic State Business Daily (ESBD), the Electronic Bidding System, and the project proposal are the official sources of advertisement and bidding information for the State and Local Lettings. Bidders should bid the project using the information found therein, including any addenda. These sources take precedence over information from other sources, including TxDOT webpages, which are unofficial and intended for informational purposes only.
Text version of this page | |||
County: | ROCKWALL | Let Date: | 10/06/23 |
Type: | SEAL COAT, PAVEMENT MKGS, MILL & INLAY | Seq No: | 3204 |
Time: | 243 WORKING DAYS | Project ID: | F 2024(123) |
Highway: | SH 66 | Contract #: | 10233204 |
Length: | 135.229 | CCSJ: | 0009-04-075 |
Limits: | |||
From: | VARIOUS LOCATIONS | Check: | $100,000 |
To: | IN THE DALLAS DISTRICT | Misc Cost: |
Estimate | $16,886,452.16 | % Over/Under | Company |
Bidder 1 | $19,193,970.72 | +13.66% | BRANNAN PAVING CO., LTD. |
Bidder 2 | $20,720,932.55 | +22.71% | CK NEWBERRY, LLC |
Item Code | Description | Unit | Quantity | Unit Est. | Bidder | Unit Bid |
3166255002 | AGGR(TY-PL GR-3LW SAC-B) | CY | 24,731.000 | 152.61 | 1 2 | 186.740 195.000 |
3166434002 | AGGR (TY-PB GR-4 OR TY-PL GR-4 ( SAC-B) | CY | 6,840.000 | 141.34 | 1 2 | 179.550 185.000 |
3166454002 | ASPH (AC-15P,AC-20-5TR, OR AC-20XP) | TON | 6,357.810 | 856.35 | 1 2 | 869.050 985.000 |
3546045 | PLANE ASPH CONC PAV (2") | SY | 45,941.000 | 3.30 | 1 2 | 5.250 4.000 |
5006001 | MOBILIZATION | LS | 1.000 | 1,548,759.76 | 1 2 | 2,545,500.000 2,000,000.000 |
5026001008 | BARRICADES, SIGNS AND TRAFFIC HANDLING | MO | 8.000 | 17,500.00 | 1 2 | 25,000.000 50,000.000 |
5336003 | RUMBLE STRIPS (SHOULDER) ASPHALT | LF | 1,552.000 | 1.80 | 1 2 | 6.750 3.000 |
5336004 | RUMBLE STRIPS (CENTERLINE) ASPHALT | LF | 776.000 | 1.80 | 1 2 | 6.750 3.000 |
5606011 | MAILBOX INSTALL-S (TWW-POST) TY 4 | EA | 58.000 | 600.00 | 1 2 | 625.000 325.000 |
5606012 | MAILBOX INSTALL-D (TWW-POST) TY 4 | EA | 4.000 | 700.00 | 1 2 | 715.000 350.000 |
5606013 | MAILBOX INSTALL-M (TWW-POST) TY 4 | EA | 6.000 | 1,000.00 | 1 2 | 975.000 725.000 |
6626109 | WK ZN PAV MRK SHT TERM (TAB)TY W | EA | 22,464.000 | 1.75 | 1 2 | 0.010 0.600 |
6626111 | WK ZN PAV MRK SHT TERM (TAB)TY Y-2 | EA | 92,869.000 | 1.60 | 1 2 | 0.010 0.600 |
6666036008 | REFL PAV MRK TY I (W)8"(SLD)(100MIL) | LF | 33,762.000 | 0.90 | 1 2 | 0.950 1.000 |
6666042008 | REFL PAV MRK TY I (W)12"(SLD)(100MIL) | LF | 2,636.000 | 2.00 | 1 2 | 6.450 4.000 |
6666048008 | REFL PAV MRK TY I (W)24"(SLD)(100MIL) | LF | 8,581.000 | 5.00 | 1 2 | 8.950 6.500 |
6666141008 | REFL PAV MRK TY I (Y)12"(SLD)(100MIL) | LF | 3,820.000 | 4.00 | 1 2 | 6.950 6.500 |
6666171008 | REFL PAV MRK TY II (W) 6" (BRK) | LF | 66,287.000 | 0.28 | 1 2 | 0.200 0.250 |
6666174008 | REFL PAV MRK TY II (W) 6" (SLD) | LF | 2,008,317.000 | 0.25 | 1 2 | 0.180 0.200 |
6666178008 | REFL PAV MRK TY II (W) 8" (SLD) | LF | 35,963.000 | 0.45 | 1 2 | 0.300 0.350 |
6666180008 | REFL PAV MRK TY II (W) 12" (SLD) | LF | 1,610.000 | 3.25 | 1 2 | 6.250 2.000 |
6666182008 | REFL PAV MRK TY II (W) 24" (SLD) | LF | 6,232.000 | 4.61 | 1 2 | 8.500 3.000 |
6666208008 | REFL PAV MRK TY II (Y) 6" (BRK) | LF | 170,310.000 | 0.24 | 1 2 | 0.200 0.250 |
6666210008 | REFL PAV MRK TY II (Y) 6" (SLD) | LF | 1,376,640.000 | 0.25 | 1 2 | 0.180 0.200 |
6666306008 | RE PM W/RET REQ TY I (W)6"(BRK)(100MIL) | LF | 30,260.000 | 0.64 | 1 2 | 0.580 0.700 |
6666309008 | RE PM W/RET REQ TY I (W)6"(SLD)(100MIL) | LF | 2,531,466.000 | 0.50 | 1 2 | 0.540 0.650 |
6666318008 | RE PM W/RET REQ TY I (Y)6"(BRK)(100MIL) | LF | 189,260.000 | 0.64 | 1 2 | 0.560 0.700 |
6666321008 | RE PM W/RET REQ TY I (Y)6"(SLD)(100MIL) | LF | 1,692,418.000 | 0.50 | 1 2 | 0.540 0.650 |
6666445008 | RE PROF PM (W)6"(SLD) RAISD PROF ONLY | LF | 264,692.000 | 0.28 | 1 2 | 0.350 1.050 |
6666446008 | RE PROF PM (Y)6"(SLD) RAISD PROF ONLY | LF | 75,450.000 | 0.28 | 1 2 | 0.350 1.050 |
6666447008 | RE PROF PM (Y)6"(BRK) RAISD PROF ONLY | LF | 5,594.000 | 0.28 | 1 2 | 0.400 1.050 |
6686077 | PREFAB PAV MRK TY C (W) (ARROW) | EA | 200.000 | 271.00 | 1 2 | 215.000 200.000 |
6686078 | PREFAB PAV MRK TY C (W) (DBL ARROW) | EA | 2.000 | 400.00 | 1 2 | 385.000 300.000 |
6686085 | PREFAB PAV MRK TY C (W) (WORD) | EA | 117.000 | 345.00 | 1 2 | 250.000 250.000 |
6686089 | PREFAB PAV MRK TY C (W) (RR XING) | EA | 16.000 | 800.00 | 1 2 | 645.000 675.000 |
6686092 | PREFAB PAV MRK TY C (W) (36")(YLD TRI) | EA | 104.000 | 40.00 | 1 2 | 50.000 55.000 |
6726007 | REFL PAV MRKR TY I-C | EA | 754.000 | 3.82 | 1 2 | 4.000 4.000 |
6726009 | REFL PAV MRKR TY II-A-A | EA | 22,935.000 | 3.82 | 1 2 | 4.000 4.000 |
6726010 | REFL PAV MRKR TY II-C-R | EA | 869.000 | 4.50 | 1 2 | 4.000 4.000 |
6776005 | ELIM EXT PAV MRK & MRKS (12") | LF | 582.000 | 3.50 | 1 2 | 4.250 3.000 |
30776011 | SP MIXES SP-C PG64-22 | TON | 5,053.860 | 169.00 | 1 2 | 227.000 260.000 |
30776075 | TACK COAT | GAL | 2,787.580 | 4.00 | 1 2 | 3.500 10.000 |
61856005002 | TMA (MOBILE OPERATION) | DAY | 190.000 | 800.00 | 1 2 | 100.000 0.010 |