COUNTY: NUECES HIGHWAY: IH 37 LENGTH: 1.5980MI CONTROL NUMBER: 0074-06-242, ETCDBE GOAL: 8.0 % PROJECT NUMBER: NH 2020(210) TYPE: FREEWAY OPERATIONAL IMPROVEMENTS TIME FOR COMPLETION: 160 WORKING DAYSGUARANTY: 100,000.00 BIDS RECEIVED UNTIL: 1:00 PM DECEMBER 03, 2019 EST.COST: 6,437,301.92 BIDS WILL BE OPENED: 1:00 PM DECEMBER 03, 2019 MAIL OR DELIVER BIDS TO: FOR PS&E PROJECT QUESTIONS CALL: TEXAS DEPARTMENT OF TRANSPORTATIONCHARLES BENAVIDEZ ATTN: CONSTRUCTION DIVISION - ROOM 1A.2 1701 SPID 200 E RIVERSIDECORPUS CHRISTI, TX 78416 AUSTIN TX 78704-1204361/808-2261 FOR QUESTIONS REGARDING A PROPOSAL CALL 512/416-2498 TO REQUEST A PROPOSAL GO TO http://www.dot.state.tx.us/business/pr.htm FOR ELECTRONIC BIDDING VISIT THE WEBSITE BELOW: http://www.txdot.gov/business/letting-bids/ebs.html ------------------------------------------------------------------------------ COUNTY CONTROL LIMITS FROM HIGHWAY PROJECT LIMITS TO ------------------------------------------------------------------------------ NUECES0074-06-242AT IH37/I69E INTERCHANGE IH 37NH 2020(210)ON EXIT 14A LENGTH: 0.3510 MILES NUECES0074-06-230FM 1694_(CALLICOATE RD) IH 37NH 2020(210)RED BIRD LANE LENGTH: 1.2470 MILES ------------------------------------------------------------------------------------------------------------- ITEM DESAPPROXIMATE ALT NO. CD. ITEM DESCRIPTIONUNITQUANTITIESBID PRICEAMOUNTSEQ ------------------------------------------------------------------------------------------------------------- 104 6009REMOVING CONC (RIPRAP)SY 1,064.0001 104 6023REMOVING CONC (CTB)LF 652.0002 105 6036REMOVING STAB BASE & ASPH PAV(15"-20")SY 452.0003 110 6001EXCAVATION (ROADWAY)CY 735.0004 110 6002EXCAVATION (CHANNEL)CY 738.0005 132 6006EMBANKMENT (FINAL)(DENS CONT)(TY C)CY 66.0006 134 6004BACKFILL (TY A OR B)STA 170.0007 164 6039DRILL SEEDING (PERM) (URBAN) (CLAY)SY 793.0008 166 6001FERTILIZERAC 0.1649 168 6001VEGETATIVE WATERINGMG 23.80010 169 6001SOIL RETENTION BLANKETS (CL 1) (TY A)SY 2,447.00011 247 6041FL BS (CMP IN PLC)(TYA GR1-2)(FNAL POS)CY 540.00012 310 6009PRIME COAT (MC-30)GAL 273.00013 316 6001ASPH (MULTI OPTION)GAL 632.00014 316 6427AGGR(TY-PB GR-4S OR TY-PB GR-4)(SAC-B)CY 1,633.00015 316 6448ASPH (AC-15P OR AC-20-5TR)GAL 47,891.00016 341 6089D-GR HMA TY-B SAC-B PG 70-22TON 16,581.00017 348 6007TBWC (MEMBRANE)GAL 24,178.00018 348 6008TBWC (ASPHALT)TON 304.00019 348 6009TBWC (AGGREGATE)(TY C)TON 5,758.00020 354 6048PLANE ASPH CONC PAV (3")SY 120,209.00021 400 6005CEM STABIL BKFLCY 95.30022 402 6001TRENCH EXCAVATION PROTECTIONLF 163.00023 416 6015DRILL SHAFT (NON - REINFORCED) (12 IN)LF 35.00024 416 6021DRILL SHAFT (SIGN MTS) (42 IN)LF 224.00025 416 6029DRILL SHAFT (RDWY ILL POLE) (30 IN)LF 30.00026 420 6066CL C CONC (RAIL FOUNDATION)CY 411.00027 432 6001RIPRAP (CONC)(4 IN)CY 357.40028 450 6016RAIL (TY T552)LF 2,655.00029 464 6003RC PIPE (CL III)(18 IN)LF 106.00030 465 6002MANH (COMPL)(PRM)(48IN)EA 1.00031 465 6135INLET (COMPL)(PSL)(FG)(5FTX5FT-4FTX4FT)EA 5.00032 479 6002ADJUSTING INLETSEA 1.00033 479 6006ADJUSTING INLET (CAP)EA 1.00034 496 6002REMOV STR (INLET)EA 1.00035 500 6001MOBILIZATIONLS 1.00036 502 6001BARRICADES, SIGNS AND TRAFFIC HANDLINGMO 8.00037 506 6021CONSTRUCTION EXITS (INSTALL) (TY 2)SY 78.00038 506 6024CONSTRUCTION EXITS (REMOVE)SY 78.00039 506 6041BIODEG EROSN CONT LOGS (INSTL) (12")LF 1,580.00040 506 6043BIODEG EROSN CONT LOGS (REMOVE)LF 1,580.00041 512 6001PORT CTB (FUR & INST)(SGL SLOPE)(TY 1)LF 4,710.00042 512 6025PORT CTB (MOVE)(SGL SLP)(TY 1)LF 1,140.00043 512 6049PORT CTB (REMOVE)(SGL SLP)(TY 1)LF 4,710.00044 542 6001REMOVE METAL BEAM GUARD FENCELF 1,457.00045 542 6002REMOVE TERMINAL ANCHOR SECTIONEA 2.00046 542 6004RM MTL BM GD FENCE TRANS (THRIE-BEAM)EA 2.00047 544 6003GUARDRAIL END TREATMENT (REMOVE)EA 6.00048 545 6005CRASH CUSH ATTEN (REMOVE)EA 7.00049 545 6007CRASH CUSH ATTEN (INSTL)(L)(N)(TL3)EA 14.00050 545 6010CRASH CUSH ATTEN (INSTL)(L)(W)(TL3)EA 1.00051 610 6009REMOVE RD IL ASM (TRANS-BASE)EA 3.00052 610 6102REPLACE LUMINAIRE W/LED (250W EQ)EA 31.00053 610 6103REPLACE LUMINAIRE W/LED (400W EQ)EA 10.00054 610 6104IN RD IL (U/P) (TY 1) (150W EQ) LEDEA 18.00055 610 6106IN RD IL (U/P) (TY 2) (150W EQ) LEDEA 23.00056 610 6130IN RD IL (TY SA) 20T-8 (250W EQ) LEDEA 1.00057 610 6214IN RD IL (TY SA) 40T-8 (250W EQ) LEDEA 3.00058 618 6019CONDT (PVC) (SCH 40) (1 1/4")LF 20.00059 618 6021CONDT (PVC) (SCH 40) (1 1/2")LF 30.00060 618 6023CONDT (PVC) (SCH 40) (2")LF 135.00061 618 6046CONDT (PVC) (SCH 80) (2")LF 850.00062 618 6064CONDT (RM) (1")LF 2,495.00063 620 6004ELEC CONDR (NO.12) INSULATEDLF 7,540.00064 620 6008ELEC CONDR (NO.8) INSULATEDLF 53,410.00065 624 6002GROUND BOX TY A (122311)W/APRONEA 51.00066 624 6028REMOVE GROUND BOXEA 46.00067 628 6002REMOVE ELECTRICAL SERVICESEA 6.00068 628 6041ELC SRV TY A 240/480 060(NS)SS(E)GC(O)EA 4.00069 636 6001ALUMINUM SIGNS (TY A)SF 26.75070 636 6002ALUMINUM SIGNS (TY G)SF 187.50071 636 6003ALUMINUM SIGNS (TY O)SF 1,411.25072 636 6007REPLACE EXISTING ALUMINUM SIGNS(TY A)SF 664.00073 636 6008REPLACE EXISTING ALUMINUM SIGNS(TY G)SF 193.50074 636 6009REPLACE EXISTING ALUMINUM SIGNS(TY O)SF 2,339.25075 644 6027IN SM RD SN SUP&AM TYS80(1)SA(P)EA 6.00076 644 6030IN SM RD SN SUP&AM TYS80(1)SA(T)EA 25.00077 644 6033IN SM RD SN SUP&AM TYS80(1)SA(U)EA 5.00078 644 6076REMOVE SM RD SN SUP&AMEA 38.00079 644 6098ISRSA TYS80(1)SA(P) (EXCLUDING SIGN)EA 8.00080 647 6001INSTALL LRSS (STRUCT STEEL)LB 1,475.20081 647 6003REMOVE LRSAEA 17.00082 650 6154INS OH SN SUP(145 FT BRDG)EA 1.00083 650 6159INS OH SN SUP(150 FT BRDG)EA 1.00084 650 6204REMOVE OVERHD SIGN SUPEA 1.00085 654 6007REMOVE SIGN WALKWAYEA 6.00086 658 6001INSTL DEL ASSM (D-SW)SZ 1(FLX)GNDEA 25.00087 658 6013INSTL DEL ASSM (D-SW)SZ (BRF)CTBEA 61.00088 658 6018INSTL DEL ASSM (D-SY)SZ 1(FLX)GNDEA 7.00089 658 6027INSTL DEL ASSM (D-SY)SZ (BRF)CTB (BI)EA 85.00090 658 6036INSTL DEL ASSM (D-DW)SZ 1(FLX)GNDEA 41.00091 658 6041INSTL DEL ASSM (D-DY)SZ 1(FLX)GNDEA 1.00092 658 6048INSTL OM ASSM (OM-2Z)(FLX)GNDEA 30.00093 658 6056INSTL OM ASSM (OM-3R)(FLX)GNDEA 2.00094 658 6061INSTL DEL ASSM (D-SW)SZ 1(BRF)GF2EA 11.00095 662 6001WK ZN PAV MRK NON-REMOV (W)4"(BRK)LF 33,744.00096 662 6004WK ZN PAV MRK NON-REMOV (W)4"(SLD)LF 27,043.00097 662 6012WK ZN PAV MRK NON-REMOV (W)8"(SLD)LF 8,920.00098 662 6013WK ZN PAV MRK NON-REMOV (W)12"(LNDP)LF 1,935.00099 662 6014WK ZN PAV MRK NON-REMOV (W)12"(SLD)LF 963.000100 662 6016WK ZN PAV MRK NON-REMOV (W)24"(SLD)LF 19,083.000101 662 6034WK ZN PAV MRK NON-REMOV (Y)4"(SLD)LF 33,744.000102 662 6052WK ZN PAV MRK REMOV (REFL) TY II-C-REA 27,043.000103 662 6063WK ZN PAV MRK REMOV (W)4"(SLD)LF 9,166.000104 662 6071WK ZN PAV MRK REMOV (W)8"(SLD)LF 2,496.000105 662 6072WK ZN PAV MRK REMOV (W)12"(LNDP)LF 335.000106 662 6095WK ZN PAV MRK REMOV (Y)4"(SLD)LF 2,408.000107 662 6109WK ZN PAV MRK SHT TERM (TAB)TY WEA 19,083.000108 666 6036REFL PAV MRK TY I (W)8"(SLD)(100MIL)LF 8,920.000109 666 6039REFL PAV MRK TY I (W)12"(LNDP)(100MIL)LF 1,935.000110 666 6042REFL PAV MRK TY I (W)12"(SLD)(100MIL)LF 963.000111 666 6167REFL PAV MRK TY II (W) 4" (BRK)LF 33,744.000112 666 6170REFL PAV MRK TY II (W) 4" (SLD)LF 27,043.000113 666 6178REFL PAV MRK TY II (W) 8" (SLD)LF 8,920.000114 666 6179REFL PAV MRK TY II (W) 12" (LNDP)LF 1,935.000115 666 6180REFL PAV MRK TY II (W) 12" (SLD)LF 963.000116 666 6207REFL PAV MRK TY II (Y) 4" (SLD)LF 19,083.000117 666 6300RE PM W/RET REQ TY I (W)4"(BRK)(100MIL)LF 33,744.000118 666 6303RE PM W/RET REQ TY I (W)4"(SLD)(100MIL)LF 27,043.000119 666 6315RE PM W/RET REQ TY I (Y)4"(SLD)(100MIL)LF 19,083.000120 668 6073PREFAB PAV MRK TY C (W) (12") (LNDP)LF 67.000121 668 6084PREFAB PAV MRK TY C (W) (NUMBER)EA 5.000122 668 6085PREFAB PAV MRK TY C (W) (WORD)EA 13.000123 668 6090PREFAB PAV MRK TY C (W) (SYMBOL)EA 11.000124 672 6008REFL PAV MRKR TY I-REA 56.000125 672 6010REFL PAV MRKR TY II-C-REA 843.000126 677 6001ELIM EXT PAV MRK & MRKS (4")LF 10,249.000127 677 6003ELIM EXT PAV MRK & MRKS (8")LF 2,542.000128 677 6005ELIM EXT PAV MRK & MRKS (12")LF 997.000129 774 6003REMOVE AND REPLACE (NARROW REACT 350)EA 1.000130 50016001GEOGRID BASE REINFORCEMENT (TY I)SY 1,621.000131 60006002REMOVE ABOVE-GROUND CONDUITLF 2,460.000132 60006008REMOVE CONDUCTORLF 58,665.000133 60006028REMOVE UNDERPASS LUMINAIRE (HPS)EA 22.000134 60006034REMOVE INDUCTION FLUORESCENT FIXTUREEA 19.000135 60006084REPLACE BREAKAWAY FUSE HOLDEREA 41.000136 60006087REPLACE CONTROL TRANS (HIGH MAST)EA 1.000137 60006091REPLACE AVIATION WARNING FIXTUREEA 6.000138 60006100REPLACE FLEX POWER CABLE OR CORDLF 170.000139 60006101REPLACE TWIST LOCK CONNECTOREA 1.000140 60006103RAISE AND LOWER RING (HIGH MAST LIGHT)EA 5.000141 60006147REPLACE 5/16" WIRE ROPEEA 1.000142 60006150REPLACE WIRE ROPE PULLEYEA 1.000143 60006151REPLACE ELECTRICAL CABLE PULLEYEA 1.000144 60006155REMOVE/REINSTL HI MAST POLE FOR REPAIREA 1.000145 60006157REPL ALUMINUM CABLE STRAPEA 1.000146 60016002PORTABLE CHANGEABLE MESSAGE SIGNEA 2.000147 60276003CONDUIT (PREPARE)LF 13,855.000148 60566001PREFORMED IN-LANE(TRANS) RUMBLE STRIPLF 80.000149 61566008REPLACE LED HIGH MAST ILLUM ASSEMBBLIESEA 6.000150 61856002TMA (STATIONARY)DAY 180.000151 61856003TMA (MOBILE OPERATION)HR 286.000152 62276001SOLAR POWERED LED WARNING SIGNEA 11.000153 63026002TEMP Q-DETECT (TY2) (1 SYS)DAY 120.000154