COUNTY: SAN PATRICIO HIGHWAY: US 181, ETCLENGTH: 1.00MI CONTROL NUMBER: 0101-03-088, ETCDBE GOAL: 7.5 % PROJECT NUMBER: STP 1802(556)HES, ETC TYPE: GRADE,BASE,SURF,STRS TIME FOR COMPLETION: 304 WORKING DAYSGUARANTY: 100,000.00 BIDS RECEIVED UNTIL: 1:00 PM AUGUST 08, 2018 EST.COST: 13,981,551.25 BIDS WILL BE OPENED: 1:00 PM AUGUST 08, 2018 MAIL OR DELIVER BIDS TO: FOR PS&E PROJECT QUESTIONS CALL: TEXAS DEPARTMENT OF TRANSPORTATIONROBERT ISASSI ATTN: CONSTRUCTION DIVISION - ROOM 1A.2 P.O. BOX 1367 200 E RIVERSIDESINTON, TX 78387 AUSTIN TX 78704-1204361/364-6402 FOR QUESTIONS REGARDING A PROPOSAL CALL 512/416-2498 TO REQUEST A PROPOSAL GO TO http://www.dot.state.tx.us/business/pr.htm FOR ELECTRONIC BIDDING VISIT THE WEBSITE BELOW: http://www.txdot.gov/business/letting-bids/ebs.html ------------------------------------------------------------------------------ COUNTY CONTROL LIMITS FROM HIGHWAY PROJECT LIMITS TO ------------------------------------------------------------------------------ SAN PATRICIO0101-03-088ON US 181 AT SH 89 INTERSECTION US 181STP 1802(556)HES. LENGTH: 0.50 MILES SAN PATRICIO0101-08-004ON SH 89 AT US 181 INTERSECTION SH 89STP 1802(557)HES. LENGTH: 0.50 MILES ------------------------------------------------------------------------------------------------------------- ITEM DESAPPROXIMATE ALT NO. CD. ITEM DESCRIPTIONUNITQUANTITIESBID PRICEAMOUNTSEQ ------------------------------------------------------------------------------------------------------------- 100 6002PREPARING ROWSTA 88.0001 104 6044REMOVING CONC (FLUME)SY 16.0002 106 6002OBLITERATING ABANDONED ROADSY 2,501.0003 110 6001EXCAVATION (ROADWAY)CY 15,426.0004 132 6005EMBANKMENT (FINAL)(ORD COMP)(TY C)CY 1,140.0005 132 6006EMBANKMENT (FINAL)(DENS CONT)(TY C)CY 193,422.0006 134 6004BACKFILL (TY A OR B)STA 159.0007 164 6033DRILL SEEDING (PERM) (RURAL) (SANDY)SY 95,785.0008 164 6041DRILL SEEDING (TEMP) (WARM)SY 47,895.0009 166 6002FERTILIZERTON 3.57010 168 6001VEGETATIVE WATERINGMG 1,486.80011 169 6002SOIL RETENTION BLANKETS (CL 1) (TY B)SY 15,973.00012 247 6041FL BS (CMP IN PLC)(TYA GR1-2)(FNAL POS)CY 15,384.00013 260 6002LIME (HYDRATED LIME (SLURRY))TON 815.00014 260 6073LIME TRT (SUBGRADE)(8")SY 41,272.00015 310 6009PRIME COAT (MC-30)GAL 7,606.00016 316 6001ASPH (MULTI OPTION)GAL 12,048.00017 316 6413ASPH(AC-15P, HFRS-2P OR CRS-2P)GAL 31,897.00018 316 6427AGGR(TY-PB GR-4S OR TY-PB GR-4)(SAC-B)CY 1,371.00019 341 6042D-GR HMA TY-D SAC-B PG70-22TON 14,996.00020 341 6076D-GR HMA TY B SAC-B PG (64-22)TON 6,095.00021 354 6021PLANE ASPH CONC PAV(0" TO 2")SY 3,255.00022 400 6005CEM STABIL BKFLCY 837.10023 400 6008CUT & RESTORE ASPH PAVINGSY 61.00024 401 6001FLOWABLE BACKFILLCY 0.62025 402 6001TRENCH EXCAVATION PROTECTIONLF 175.00026 403 6001TEMPORARY SPL SHORINGSF 587.00027 409 6002PRESTR CONC PIL (18 IN SQ)LF 3,968.00028 416 6018DRILL SHAFT (SIGN MTS) (24 IN)LF 114.00029 416 6029DRILL SHAFT (RDWY ILL POLE) (30 IN)LF 96.00030 420 6011CL B CONC (FLUME)CY 16.00031 420 6013CL C CONC (ABUT)CY 111.60032 420 6029CL C CONC (CAP)CY 81.20033 420 6037CL C CONC (COLUMN)CY 54.50034 420 6043CL C CONC (FOOTING)CY 57.60035 420 6066CL C CONC (RAIL FOUNDATION)CY 19.00036 422 6001REINF CONC SLABSF 27,600.00037 422 6015APPROACH SLABCY 188.80038 423 6001RETAINING WALL (MSE)SF 74,012.00039 425 6039PRESTR CONC GIRDER (TX54)LF 3,434.24040 432 6001RIPRAP (CONC)(4 IN)CY 311.25041 432 6002RIPRAP (CONC)(5 IN)CY 278.00042 432 6008RIPRAP (CONC)(CL B)(RR8&RR9)CY 204.40043 432 6026RIPRAP (STONE COMMON)(DRY)(18 IN)CY 178.00044 432 6045RIPRAP (MOW STRIP)(4 IN)CY 116.00045 432 6046RIPRAP (MOW STRIP)(5 IN)CY 206.00046 450 6023RAIL (TY SSTR)LF 5,695.00047 451 6007RETROFIT RAIL (TY T223)LF 75.00048 454 6001SEALED EXPANSION JOINT (4 IN) (SEJ - A)LF 178.00049 462 6007CONC BOX CULV (5 FT X 3 FT)LF 3,122.00050 462 6054CONC BOX CULV (6 FT X 3 FT)(EXTEND)LF 488.00051 462 6055CONC BOX CULV (6 FT X 4 FT)(EXTEND)LF 20.00052 462 6133CONC BOX CULV (5 FT X 6.5 FT)(EXTEND)LF 3.00053 464 6003RC PIPE (CL III)(18 IN)LF 443.00054 465 6005JCTBOX(COMPL)(PJB)(3FTX3FT)EA 4.00055 465 6235INLET (COMPL)(RWI)(TY I)EA 4.00056 465 6284MANHOLE (COMPL)(SPECIAL)EA 6.00057 466 6184WINGWALL (PW - 1) (HW=9 FT)EA 1.00058 467 6182SET (TY I)(S= 5 FT)(HW= 5 FT)(4:1) (C)EA 2.00059 467 6184SET (TY I)(S= 5 FT)(HW= 5 FT)(6:1) (P)EA 6.00060 467 6215SET (TY I)(S= 6 FT)(HW= 4 FT)(6:1) (P)EA 4.00061 467 6219SET (TY I)(S= 6 FT)(HW= 5 FT)(4:1) (C)EA 4.00062 467 6220SET (TY I)(S= 6 FT)(HW= 5 FT)(6:1) (C)EA 2.00063 467 6362SET (TY II) (18 IN) (RCP) (6: 1) (C)EA 8.00064 480 6001CLEAN EXIST CULVERTSEA 12.00065 496 6004REMOV STR (SET)EA 7.00066 496 6005REMOV STR (WINGWALL)EA 1.00067 496 6007REMOV STR (PIPE)LF 75.00068 500 6001MOBILIZATIONLS 1.00069 502 6001BARRICADES, SIGNS AND TRAFFIC HANDLINGMO 18.00070 506 6020CONSTRUCTION EXITS (INSTALL) (TY 1)SY 222.00071 506 6024CONSTRUCTION EXITS (REMOVE)SY 222.00072 506 6038TEMP SEDMT CONT FENCE (INSTALL)LF 1,570.00073 506 6039TEMP SEDMT CONT FENCE (REMOVE)LF 1,570.00074 512 6005PORT CTB (FUR & INST)(F-SHAPE)(TY 1)LF 7,380.00075 512 6029PORT CTB (MOVE)(F-SHAPE)(TY 1)LF 2,970.00076 512 6053PORT CTB (REMOVE)(F-SHAPE)(TY 1)LF 7,380.00077 529 6005CONC CURB (MONO) (TY II)LF 19.00078 530 6008TURNOUTS (ACP)SY 33.00079 530 6019DRIVEWAYS (ACP)(TYPE 1)SY 484.00080 530 6021DRIVEWAYS (ACP) (TYPE 2)SY 189.00081 533 6001RUMBLE STRIPS (SHOULDER)LF 25,070.00082 540 6001MTL W-BEAM GD FEN (TIM POST)LF 1,712.50083 540 6006MTL BEAM GD FEN TRANS (THRIE-BEAM)EA 5.00084 540 6016DOWNSTREAM ANCHOR TERMINAL SECTIONEA 3.00085 540 6018MTL BM GD FEN TRANS (NON - SYM)EA 2.00086 540 6033MTL BM GD FEN (LONG SPAN SYSTEM)EA 1.00087 542 6001REMOVE METAL BEAM GUARD FENCELF 800.00088 542 6002REMOVE TERMINAL ANCHOR SECTIONEA 2.00089 542 6004RM MTL BM GD FENCE TRANS (THRIE-BEAM)EA 3.00090 544 6001GUARDRAIL END TREATMENT (INSTALL)EA 7.00091 544 6003GUARDRAIL END TREATMENT (REMOVE)EA 5.00092 545 6001CRASH CUSH ATTEN (INSTL)EA 5.00093 545 6003CRASH CUSH ATTEN (MOVE & RESET)EA 4.00094 545 6005CRASH CUSH ATTEN (REMOVE)EA 5.00095 545 6014CRASH CUSH ATTEN (INSTL)(R)(N)(70)EA 2.00096 610 6102REPLACE LUMINAIRE W/LED (250W EQ)EA 18.00097 610 6104IN RD IL (U/P) (TY 1) (150W EQ) LEDEA 4.00098 610 6214IN RD IL (TY SA) 40T-8 (250W EQ) LEDEA 12.00099 618 6023CONDT (PVC) (SCH 40) (2")LF 4,560.000100 618 6024CONDT (PVC) (SCH 40) (2") (BORE)LF 370.000101 618 6064CONDT (RM) (1")LF 550.000102 620 6005ELEC CONDR (NO.10) BARELF 190.000103 620 6006ELEC CONDR (NO.10) INSULATEDLF 380.000104 620 6007ELEC CONDR (NO.8) BARELF 5,238.000105 620 6008ELEC CONDR (NO.8) INSULATEDLF 10,476.000106 624 6002GROUND BOX TY A (122311)W/APRONEA 12.000107 628 6002REMOVE ELECTRICAL SERVICESEA 2.000108 628 6041ELC SRV TY A 240/480 060(NS)SS(E)GC(O)EA 2.000109 636 6001ALUMINUM SIGNS (TY A)SF 2.000110 636 6002ALUMINUM SIGNS (TY G)SF 525.000111 644 6027IN SM RD SN SUP&AM TYS80(1)SA(P)EA 29.000112 644 6028IN SM RD SN SUP&AM TYS80(1)SA(P-BM)EA 6.000113 644 6030IN SM RD SN SUP&AM TYS80(1)SA(T)EA 12.000114 644 6032IN SM RD SN SUP&AM TYS80(1)SA(T-EXAL)EA 4.000115 644 6033IN SM RD SN SUP&AM TYS80(1)SA(U)EA 4.000116 644 6038IN SM RD SN SUP&AM TYS80(1)SA(U-EXAL)EA 2.000117 644 6064IN BRIDGE MNT CLEARANCE SGN ASSM(TY N)EA 2.000118 644 6076REMOVE SM RD SN SUP&AMEA 53.000119 644 6087IN SRSS & AM (RAIL)(130 MPH)(P MOUNT)EA 3.000120 647 6001INSTALL LRSS (STRUCT STEEL)LB 3,023.800121 647 6003REMOVE LRSAEA 3.000122 658 6001INSTL DEL ASSM (D-SW)SZ 1(FLX)GNDEA 17.000123 658 6013INSTL DEL ASSM (D-SW)SZ (BRF)CTBEA 51.000124 658 6026INSTL DEL ASSM (D-SY)SZ (BRF)CTBEA 6.000125 658 6036INSTL DEL ASSM (D-DW)SZ 1(FLX)GNDEA 35.000126 658 6041INSTL DEL ASSM (D-DY)SZ 1(FLX)GNDEA 4.000127 658 6048INSTL OM ASSM (OM-2Z)(FLX)GNDEA 14.000128 658 6061INSTL DEL ASSM (D-SW)SZ 1(BRF)GF2EA 19.000129 658 6064INSTL DEL ASSM (D-SY)SZ 1(BRF)GF2EA 9.000130 662 6001WK ZN PAV MRK NON-REMOV (W)4"(BRK)LF 7,317.000131 662 6002WK ZN PAV MRK NON-REMOV (W)4"(DOT)LF 426.000132 662 6004WK ZN PAV MRK NON-REMOV (W)4"(SLD)LF 30,194.000133 662 6012WK ZN PAV MRK NON-REMOV (W)8"(SLD)LF 6,177.000134 662 6014WK ZN PAV MRK NON-REMOV (W)12"(SLD)LF 659.000135 662 6034WK ZN PAV MRK NON-REMOV (Y)4"(SLD)LF 31,783.000136 662 6052WK ZN PAV MRK REMOV (REFL) TY II-C-REA 354.000137 662 6057WK ZN PAV MRK REMOV (TRAF BTN) TY WLF 360.000138 662 6059WK ZN PAV MRK REMOV (TRAF BTN) TY YLF 183.000139 662 6109WK ZN PAV MRK SHT TERM (TAB)TY WEA 4,239.000140 662 6110WK ZN PAV MRK SHT TERM (TAB)TY YEA 264.000141 666 6005REFL PAV MRK TY I (W)4"(DOT)(090MIL)LF 300.000142 666 6035REFL PAV MRK TY I (W)8"(SLD)(090MIL)LF 10,941.000143 666 6041REFL PAV MRK TY I (W)12"(SLD)(090MIL)LF 482.000144 666 6146REFL PAV MRK TY I (Y)24"(SLD)(090MIL)LF 440.000145 666 6299RE PM W/RET REQ TY I (W)4"(BRK)(090MIL)LF 5,131.000146 666 6302RE PM W/RET REQ TY I (W)4"(SLD)(090MIL)LF 23,877.000147 666 6314RE PM W/RET REQ TY I (Y)4"(SLD)(090MIL)LF 24,705.000148 668 6076PREFAB PAV MRK TY C (W) (24") (SLD)LF 148.000149 668 6077PREFAB PAV MRK TY C (W) (ARROW)EA 24.000150 668 6085PREFAB PAV MRK TY C (W) (WORD)EA 20.000151 668 6092PREFAB PAV MRK TY C (W) (36")(YLD TRI)EA 33.000152 672 6007REFL PAV MRKR TY I-CEA 9.000153 672 6008REFL PAV MRKR TY I-REA 42.000154 672 6009REFL PAV MRKR TY II-A-AEA 362.000155 672 6010REFL PAV MRKR TY II-C-REA 851.000156 677 6001ELIM EXT PAV MRK & MRKS (4")LF 79,895.000157 677 6003ELIM EXT PAV MRK & MRKS (8")LF 4,842.000158 677 6005ELIM EXT PAV MRK & MRKS (12")LF 659.000159 685 6006REMOV RDSD FLSH BCN AM (SOLAR PWRD)EA 2.000160 30206001REMOVE SHOULDER TEXTURINGLF 11,652.000161 60006009REPLACE CONDUCTORLF 11,935.000162 60006052REPLACE ELECTRICAL SERVICEEA 2.000163 60006084REPLACE BREAKAWAY FUSE HOLDEREA 18.000164 60016001PORTABLE CHANGEABLE MESSAGE SIGNDAY 608.000165 60276003CONDUIT (PREPARE)LF 3,430.000166 61856002TMA (STATIONARY)DAY 50.000167 61856003TMA (MOBILE OPERATION)HR 320.000168