COUNTY: SMITH HIGHWAY: US 69 LENGTH: 0.9480MI CONTROL NUMBER: 0191-01-063 DBE GOAL: 7.5 % PROJECT NUMBER: NH 2013(216) TYPE: GR, STRS, ACP SURF, PVMT MRKG, MBGF TIME FOR COMPLETION: 430 WORKING DAYSGUARANTY: 100,000.00 BIDS RECEIVED UNTIL: 1:00 PM AUGUST 08, 2018*EST.COST: 16,549,021.48 BIDS WILL BE OPENED: 1:00 PM AUGUST 08, 2018 MAIL OR DELIVER BIDS TO: FOR PS&E PROJECT QUESTIONS CALL: TEXAS DEPARTMENT OF TRANSPORTATIONPAUL SCHNEIDER ATTN: CONSTRUCTION DIVISION - ROOM 1A.2 15986 SH 155-S 200 E RIVERSIDETYLER, TX 75703 AUSTIN TX 78704-1204903/509-9066 FOR QUESTIONS REGARDING A PROPOSAL CALL 512/416-2498 TO REQUEST A PROPOSAL GO TO http://www.dot.state.tx.us/business/pr.htm FOR ELECTRONIC BIDDING VISIT THE WEBSITE BELOW: http://www.txdot.gov/business/letting-bids/ebs.html LIMITS FROM: AT FM 346, E OF FLINT LIMITS TO: . ------------------------------------------------------------------------------------------------------------- ITEM DESAPPROXIMATE ALT NO. CD. ITEM DESCRIPTIONUNITQUANTITIESBID PRICEAMOUNTSEQ ------------------------------------------------------------------------------------------------------------- 100 6002PREPARING ROWSTA 65.0901 104 6009REMOVING CONC (RIPRAP)SY 130.0002 105 6070REMOVING STAB BASE & ASPH PAV (6" - 8")SY 26,743.0003 110 6001EXCAVATION (ROADWAY)CY 20,121.0004 110 6003EXCAVATION (SPECIAL)CY 19,500.0005 132 6006EMBANKMENT (FINAL)(DENS CONT)(TY C)CY 51,283.0006 160 6003FURNISHING AND PLACING TOPSOIL (4")SY 9,700.0007 164 6054BOND FBR MTRX SEED (PERM)(RURAL)(SAND)SY 154,000.0008 164 6055BONDED FBR MTRX SEED (TEMP)(WARM)SY 31,000.0009 164 6056BONDED FBR MTRX SEED (TEMP)(COOL)SY 31,000.00010 168 6001VEGETATIVE WATERINGMG 1,754.00011 275 6001CEMENTTON 819.00012 275 6010CEMENT TREAT (SUBGRADE) (8")SY 45,508.00013 316 6406ASPH (AC-20XP, AC-10-2TR, OR AC-20-5TR)GAL 26,292.00014 316 6407AGGR (TY-PD GR-3 OR TY-PL GR-3)CY 626.00015 344 6034SUPERPAVE MIXTURES SP-C PG64-22TON 23,670.00016 344 6047SUPERPAVE MIXTURES SP-C SAC-A PG70-22TON 6,836.00017 344 6172SUPERPAVE MIXTURES SP-C PG64-22(LEV-UP)TON 8,403.00018 351 6002FLEXIBLE PAVEMENT STRUCTURE REPAIR(6")SY 400.00019 354 6023PLANE ASPH CONC PAV(0" TO 4")SY 4,790.00020 400 6005CEM STABIL BKFLCY 161.00021 400 6006CUT & RESTORING PAVSY 415.00022 401 6001FLOWABLE BACKFILLCY 1,647.00023 402 6001TRENCH EXCAVATION PROTECTIONLF 2,945.00024 403 6001TEMPORARY SPL SHORINGSF 2,316.00025 416 6004DRILL SHAFT (36 IN)LF 2,067.00026 416 6018DRILL SHAFT (SIGN MTS) (24 IN)LF 64.00027 416 6029DRILL SHAFT (RDWY ILL POLE) (30 IN)LF 170.00028 420 6013CL C CONC (ABUT)CY 78.90029 420 6029CL C CONC (CAP)CY 189.20030 420 6037CL C CONC (COLUMN)CY 103.70031 420 6066CL C CONC (RAIL FOUNDATION)CY 196.00032 420 6076CL E CONC (SEAL SLAB)CY 140.00033 422 6001REINF CONC SLABSF 55,200.00034 422 6015APPROACH SLABCY 211.80035 423 6001RETAINING WALL (MSE)SF 29,949.00036 425 6038PRESTR CONC GIRDER (TX46)LF 8,096.91037 432 6001RIPRAP (CONC)(4 IN)CY 796.00038 432 6002RIPRAP (CONC)(5 IN)CY 529.00039 432 6036RIPRAP (STONE PROTECTION)(30 IN)CY 1,596.00040 432 6045RIPRAP (MOW STRIP)(4 IN)CY 118.00041 450 6014RAIL (TY T551)LF 4,932.00042 450 6027RAIL (TY T80SS)LF 598.00043 454 6001SEALED EXPANSION JOINT (4 IN) (SEJ - A)LF 252.00044 462 6018CONC BOX CULV (7 FT X 7 FT)LF 360.00045 462 6069CONC BOX CULV (9 FT X 6 FT)(EXTEND)LF 120.00046 462 6070CONC BOX CULV (9 FT X 7 FT)(EXTEND)LF 156.00047 464 6003RC PIPE (CL III)(18 IN)LF 1,226.00048 464 6004RC PIPE (CL III)(21 IN)LF 111.00049 464 6005RC PIPE (CL III)(24 IN)LF 128.00050 464 6007RC PIPE (CL III)(30 IN)LF 143.00051 464 6008RC PIPE (CL III)(36 IN)LF 230.00052 464 6010RC PIPE (CL III)(48 IN)LF 140.00053 464 6025RC PIPE (CL V)(18 IN)LF 728.00054 465 6002MANH (COMPL)(PRM)(48IN)EA 1.00055 465 6005JCTBOX(COMPL)(PJB)(3FTX3FT)EA 12.00056 465 6029INLET (COMPL)(PCU)(3FT)(NONE)EA 3.00057 465 6030INLET (COMPL)(PCU)(3FT)(LEFT)EA 2.00058 465 6031INLET (COMPL)(PCU)(3FT)(RIGHT)EA 1.00059 465 6063INLET (COMPL)(PSL)(RH)(4FTX4FT)EA 2.00060 465 6068INLET (COMPL)(PSL)(RH)(6FTX6FT)EA 1.00061 465 6126INLET (COMPL)(PSL)(FG)(3FTX3FT-3FTX3FT)EA 1.00062 465 6128INLET (COMPL)(PSL)(FG)(4FTX4FT-4FTX4FT)EA 1.00063 465 6148INLET(COMPL)(PSL)(SFG)(3FTX5FT-3FTX5FT)EA 6.00064 465 6153INLET (COMPL)(PAZD)(RC)(4FTX4FT)EA 1.00065 465 6178INLET (COMPL)(TY MSE1)EA 2.00066 465 6179INLET (COMPL)(TY MSE2)EA 10.00067 466 6097HEADWALL (CH - PW - 0) (DIA= 24 IN)EA 1.00068 466 6142WINGWALL (FW - 0) (HW=10 FT)EA 1.00069 466 6143WINGWALL (FW - 0) (HW=11 FT)EA 2.00070 466 6156WINGWALL (FW - 0) (HW=9 FT)EA 2.00071 467 6356SET (TY II) (18 IN) (RCP) (3: 1) (C)EA 3.00072 467 6358SET (TY II) (18 IN) (RCP) (4: 1) (C)EA 13.00073 467 6363SET (TY II) (18 IN) (RCP) (6: 1) (P)EA 20.00074 467 6374SET (TY II) (21 IN) (RCP) (6: 1) (P)EA 4.00075 467 6390SET (TY II) (24 IN) (RCP) (4: 1) (C)EA 1.00076 467 6395SET (TY II) (24 IN) (RCP) (6: 1) (P)EA 2.00077 467 6423SET (TY II) (30 IN) (RCP) (6: 1) (P)EA 6.00078 467 6454SET (TY II) (36 IN) (RCP) (6: 1) (P)EA 6.00079 467 6480SET (TY II) (48 IN) (RCP) (6: 1) (P)EA 2.00080 479 6006ADJUSTING INLET (CAP)EA 1.00081 480 6001CLEAN EXIST CULVERTSEA 3.00082 496 6002REMOV STR (INLET)EA 1.00083 496 6016REMOV STR (PIPE)EA 25.00084 500 6001MOBILIZATIONLS 1.00085 502 6001BARRICADES, SIGNS AND TRAFFIC HANDLINGMO 24.00086 506 6002ROCK FILTER DAMS (INSTALL) (TY 2)LF 3,330.00087 506 6003ROCK FILTER DAMS (INSTALL) (TY 3)LF 1,300.00088 506 6004ROCK FILTER DAMS (INSTALL) (TY 4)LF 54.00089 506 6011ROCK FILTER DAMS (REMOVE)LF 4,630.00090 506 6020CONSTRUCTION EXITS (INSTALL) (TY 1)SY 2,918.00091 506 6024CONSTRUCTION EXITS (REMOVE)SY 2,918.00092 506 6029EARTHWORK (EROSN & SEDMT CONT, IN VEH)CY 1,000.00093 506 6030BACKHOE WORK (EROSION & SEDMT CONT)HR 80.00094 506 6038TEMP SEDMT CONT FENCE (INSTALL)LF 7,559.00095 506 6039TEMP SEDMT CONT FENCE (REMOVE)LF 7,559.00096 506 6040BIODEG EROSN CONT LOGS (INSTL) (8")LF 717.00097 506 6043BIODEG EROSN CONT LOGS (REMOVE)LF 717.00098 508 6001CONSTRUCTING DETOURSSY 4,470.00099 512 6005PORT CTB (FUR & INST)(F-SHAPE)(TY 1)LF 4,920.000100 512 6010PORT CTB (FUR & INST)(LOW PROF)(TY 2)LF 160.000101 512 6021PORT CTB (DES SOURCE)(LOW PROF)(TY 1)LF 860.000102 512 6029PORT CTB (MOVE)(F-SHAPE)(TY 1)LF 5,430.000103 512 6033PORT CTB (MOVE)(LOW PROF)(TY 1)LF 800.000104 512 6034PORT CTB (MOVE)(LOW PROF)(TY 2)LF 140.000105 512 6041PORT CTB (STKPL)(F-SHAPE)(TY 1)LF 4,920.000106 512 6045PORT CTB (STKPL)(LOW PROF)(TY 1)LF 860.000107 512 6046PORT CTB (STKPL)(LOW PROF)(TY 2)LF 160.000108 514 6001PERM CTB (SGL SLOPE) (TY 1) (42 )LF 1,350.000109 514 6040PERM CTB (SSCB)(TY 3)(MOD)LF 330.000110 529 6008CONC CURB & GUTTER (TY II)LF 4,986.000111 530 6005DRIVEWAYS (ACP)SY 1,594.000112 540 6001MTL W-BEAM GD FEN (TIM POST)LF 1,250.000113 540 6006MTL BEAM GD FEN TRANS (THRIE-BEAM)EA 2.000114 540 6016DOWNSTREAM ANCHOR TERMINAL SECTIONEA 4.000115 540 6017MTL BM GD FEN (LONG SPAN SYSTEM)LF 100.000116 540 6020MTL W - BEAM GD FEN (LOW FILL CULVERT)LF 350.000117 542 6001REMOVE METAL BEAM GUARD FENCELF 913.000118 544 6001GUARDRAIL END TREATMENT (INSTALL)EA 6.000119 544 6003GUARDRAIL END TREATMENT (REMOVE)EA 2.000120 545 6001CRASH CUSH ATTEN (INSTL)EA 13.000121 545 6003CRASH CUSH ATTEN (MOVE & RESET)EA 12.000122 545 6005CRASH CUSH ATTEN (REMOVE)EA 11.000123 556 6006PIPE UNDERDRAINS (TY 6) (6")LF 450.000124 556 6010PIPE UNDERDRAINS FILTER MATL(DRAIN PMT)SY 3,688.000125 560 6003MAILBOX INSTALL-M (TWG-POST) TY 1EA 1.000126 560 6004MAILBOX INSTALL-S (TWG-POST) TY 2EA 4.000127 560 6005MAILBOX INSTALL-D (TWG-POST) TY 2EA 1.000128 610 6104IN RD IL (U/P) (TY 1) (150W EQ) LEDEA 4.000129 610 6106IN RD IL (U/P) (TY 2) (150W EQ) LEDEA 4.000130 610 6214IN RD IL (TY SA) 40T-8 (250W EQ) LEDEA 17.000131 618 6023CONDT (PVC) (SCH 40) (2")LF 2,442.000132 618 6024CONDT (PVC) (SCH 40) (2") (BORE)LF 766.000133 618 6062CONDT (RM) (3/4")LF 361.000134 620 6003ELEC CONDR (NO.12) BARELF 396.000135 620 6004ELEC CONDR (NO.12) INSULATEDLF 792.000136 620 6007ELEC CONDR (NO.8) BARELF 3,333.000137 620 6008ELEC CONDR (NO.8) INSULATEDLF 7,148.000138 624 6001GROUND BOX TY A (122311)EA 1.000139 624 6002GROUND BOX TY A (122311)W/APRONEA 10.000140 628 6009ELC SRV TY A 120/240 060(NS)SS(E)SP(O)EA 3.000141 636 6002ALUMINUM SIGNS (TY G)SF 816.000142 644 6001IN SM RD SN SUP&AM TY10BWG(1)SA(P)EA 24.000143 644 6004IN SM RD SN SUP&AM TY10BWG(1)SA(T)EA 17.000144 644 6007IN SM RD SN SUP&AM TY10BWG(1)SA(U)EA 3.000145 644 6030IN SM RD SN SUP&AM TYS80(1)SA(T)EA 2.000146 644 6033IN SM RD SN SUP&AM TYS80(1)SA(U)EA 4.000147 644 6064IN BRIDGE MNT CLEARANCE SGN ASSM(TY N)EA 4.000148 644 6066IN SM RD SN SUP&AM (RAIL MOUNT)EA 4.000149 644 6076REMOVE SM RD SN SUP&AMEA 59.000150 647 6001INSTALL LRSS (STRUCT STEEL)LB 3,406.660151 658 6001INSTL DEL ASSM (D-SW)SZ 1(FLX)GNDEA 18.000152 658 6013INSTL DEL ASSM (D-SW)SZ (BRF)CTBEA 49.000153 658 6026INSTL DEL ASSM (D-SY)SZ (BRF)CTBEA 6.000154 658 6027INSTL DEL ASSM (D-SY)SZ (BRF)CTB (BI)EA 24.000155 658 6036INSTL DEL ASSM (D-DW)SZ 1(FLX)GNDEA 19.000156 658 6061INSTL DEL ASSM (D-SW)SZ 1(BRF)GF2EA 8.000157 658 6062INSTL DEL ASSM (D-SW)SZ 1(BRF)GF2(BI)EA 7.000158 658 6068INSTL DEL ASSM (D-DY)SZ 1(BRF)GF2EA 4.000159 662 6001WK ZN PAV MRK NON-REMOV (W)4"(BRK)LF 2,940.000160 662 6002WK ZN PAV MRK NON-REMOV (W)4"(DOT)LF 55.000161 662 6004WK ZN PAV MRK NON-REMOV (W)4"(SLD)LF 19,167.000162 662 6012WK ZN PAV MRK NON-REMOV (W)8"(SLD)LF 2,710.000163 662 6034WK ZN PAV MRK NON-REMOV (Y)4"(SLD)LF 18,979.000164 662 6060WK ZN PAV MRK REMOV (W)4"(BRK)LF 1,854.000165 662 6063WK ZN PAV MRK REMOV (W)4"(SLD)LF 7,979.000166 662 6075WK ZN PAV MRK REMOV (W)24"(SLD)LF 451.000167 662 6095WK ZN PAV MRK REMOV (Y)4"(SLD)LF 11,688.000168 662 6109WK ZN PAV MRK SHT TERM (TAB)TY WEA 751.000169 662 6111WK ZN PAV MRK SHT TERM (TAB)TY Y-2EA 453.000170 666 6009REFL PAV MRK TY I (W)4"(LNDP)(100MIL)LF 130.000171 666 6036REFL PAV MRK TY I (W)8"(SLD)(100MIL)LF 4,291.000172 666 6048REFL PAV MRK TY I (W)24"(SLD)(100MIL)LF 92.000173 666 6099REF PAV MRK TY I(W)18"(YLD TRI)(100MIL)EA 20.000174 666 6102REF PAV MRK TY I(W)36"(YLD TRI)(100MIL)EA 8.000175 666 6224PAVEMENT SEALER 4"LF 3,412.000176 666 6300RE PM W/RET REQ TY I (W)4"(BRK)(100MIL)LF 2,605.000177 666 6303RE PM W/RET REQ TY I (W)4"(SLD)(100MIL)LF 18,238.000178 666 6312RE PM W/RET REQ TY I (Y)4"(BRK)(100MIL)LF 40.000179 666 6315RE PM W/RET REQ TY I (Y)4"(SLD)(100MIL)LF 19,125.000180 668 6077PREFAB PAV MRK TY C (W) (ARROW)EA 12.000181 668 6085PREFAB PAV MRK TY C (W) (WORD)EA 10.000182 672 6009REFL PAV MRKR TY II-A-AEA 182.000183 672 6010REFL PAV MRKR TY II-C-REA 345.000184 677 6001ELIM EXT PAV MRK & MRKS (4")LF 52,590.000185 677 6003ELIM EXT PAV MRK & MRKS (8")LF 452.000186 677 6007ELIM EXT PAV MRK & MRKS (24")LF 852.000187 677 6008ELIM EXT PAV MRK & MRKS (ARROW)EA 4.000188 677 6012ELIM EXT PAV MRK & MRKS (WORD)EA 4.000189 678 6001PAV SURF PREP FOR MRK (4")LF 3,412.000190 681 6001TEMP TRAF SIGNALSEA 2.000191 60016001PORTABLE CHANGEABLE MESSAGE SIGNDAY 28.000192 60016002PORTABLE CHANGEABLE MESSAGE SIGNEA 2.000193 61856001TMA (STATIONARY)EA 2.000194 61856005 TMA (MOBILE OPERATION)DAY 40.000195 * INCLUDES FORCE ACCOUNT WORK AMOUNTS AS FOLLOWS: CONTRACTOR FORCE ACCOUNT WORK (PART) $30,000.00