COUNTY: NAVARRO HIGHWAY: FM 667 LENGTH: 14.6320MI CONTROL NUMBER: 0997-03-007, ETCDBE GOAL: 4.0 % PROJECT NUMBER: STP 2018(888) TYPE: ACP OVERLAY; GR; STR; PMVT MKGS TIME FOR COMPLETION: 614 WORKING DAYSGUARANTY: 100,000.00 BIDS RECEIVED UNTIL: 1:00 PM MAY 02, 2018*EST.COST: 20,052,562.98 BIDS WILL BE OPENED: 1:00 PM MAY 02, 2018 MAIL OR DELIVER BIDS TO: FOR PS&E PROJECT QUESTIONS CALL: TEXAS DEPARTMENT OF TRANSPORTATIONDARWIN J. MYERS, P.E ATTN: CONSTRUCTION DIVISION - ROOM 1A.2 100 SW CR 1000 200 E RIVERSIDECORSICANA, TX 75110 AUSTIN TX 78704-1204903/874-4351 FOR QUESTIONS REGARDING A PROPOSAL CALL 512/416-2498 TO REQUEST A PROPOSAL GO TO http://www.dot.state.tx.us/business/pr.htm FOR ELECTRONIC BIDDING VISIT THE WEBSITE BELOW: http://www.txdot.gov/business/letting-bids/ebs.html ------------------------------------------------------------------------------ COUNTY CONTROL LIMITS FROM HIGHWAY PROJECT LIMITS TO ------------------------------------------------------------------------------ NAVARRO0997-03-007SH 31 FM 667STP 2018(888)FM 744 LENGTH: 4.85 MILES NAVARRO0747-02-018SH 22 FM 667STP 2018(888)ELLIS COUNTY LINE LENGTH: 2.4760 MILES NAVARRO0747-02-019FM 744 FM 667STP 2018(888)SH 22 LENGTH: 7.3060 MILES ------------------------------------------------------------------------------------------------------------- ITEM DESAPPROXIMATE ALT NO. CD. ITEM DESCRIPTIONUNITQUANTITIESBID PRICEAMOUNTSEQ ------------------------------------------------------------------------------------------------------------- 100 6002PREPARING ROWSTA 770.5401 104 6011REMOVING CONC (MEDIANS)SY 64.0002 104 6017REMOVING CONC (DRIVEWAYS)SY 613.0003 104 6022REMOVING CONC (CURB AND GUTTER)LF 100.0004 110 6001EXCAVATION (ROADWAY)CY 3,378.0005 132 6006EMBANKMENT (FINAL)(DENS CONT)(TY C)CY 25,105.0006 134 6004BACKFILL (TY A OR B)STA 770.5407 160 6003FURNISHING AND PLACING TOPSOIL (4")SY 541,400.0008 164 6035DRILL SEEDING (PERM) (RURAL) (CLAY)SY 541,400.0009 164 6051DRILL SEED (TEMP)(WARM OR COOL)SY 541,400.00010 168 6001VEGETATIVE WATERINGMG 27,070.00011 247 6133FL BS (RDWY DEL) (TY D GR 1-2)TON 740.00012 247 6317FL BS (CMP IN PLC)(TY D GR 1-2) (5")SY 239,764.00013 251 6114REWORK BS MATL (TY B)(10")(OC)SY 188,357.00014 260 6002LIME (HYDRATED LIME (SLURRY))TON 8,131.00015 260 6011LIME TRT (EXST MATL) (12")SY 256,859.00016 275 6001CEMENTTON 2,523.00017 275 6002CEMENT TREAT (EXIST MATL) (6")SY 248,312.00018 305 6014SALV,HAUL& STKPL RCL APH PV(VAR DEPTH)SY 6,745.00019 314 6021EMULS ASPH (PRIME)(MS-2 OR SS-1)GAL 47,982.00020 316 6024ASPH (CRS-2P)GAL 39,995.87021 316 6029ASPH (RC-250)GAL 22,417.00022 316 6403AGGR (TY-B GR-5 OR TY-L GR-5)CY 700.00023 316 6419ASPH (AC-15P, AC-20-5TR OR AC-20XP)GAL 120,467.00024 316 6434AGGR (TY-PB GR-4 OR TY-PL GR-4 ( SAC-B)CY 2,043.00025 316 6440AGGR (TY-B GR-3 OR TY-L GR-3)(SAC-B)CY 1,543.00026 344 6104SUPERPAVE MIXTURES SP-D SAC-B PG64-22TON 522.00027 361 6044FULL - DEPTH REPAIR CPJR (9")SY 898.00028 400 6005CEM STABIL BKFLCY 897.00029 400 6008CUT & RESTORE ASPH PAVINGSY 356.00030 402 6001TRENCH EXCAVATION PROTECTIONLF 408.00031 403 6001TEMPORARY SPL SHORINGSF 11,573.00032 432 6001RIPRAP (CONC)(4 IN)CY 61.00033 432 6024RIPRAP (STONE COMMON)(DRY)(12 IN)CY 179.00034 432 6025RIRRAP (STONE COMMON)(DRY)(15 IN)CY 288.00035 432 6026RIPRAP (STONE COMMON)(DRY)(18 IN)CY 840.00036 432 6045RIPRAP (MOW STRIP)(4 IN)CY 254.00037 460 6002CMP (GAL STL 18 IN)LF 2,375.00038 460 6003CMP (GAL STL 24 IN)LF 177.00039 460 6004CMP (GAL STL 30 IN)LF 178.00040 460 6005CMP (GAL STL 36 IN)LF 72.00041 462 6001CONC BOX CULV (3 FT X 2 FT)LF 84.00042 462 6020CONC BOX CULV (8 FT X 5 FT)LF 120.00043 462 6048CONC BOX CULV (4 FT X 3 FT)(EXTEND)LF 14.00044 462 6049CONC BOX CULV (4 FT X 4 FT)(EXTEND)LF 16.00045 462 6051CONC BOX CULV (5 FT X 3 FT)(EXTEND)LF 7.00046 462 6052CONC BOX CULV (5 FT X 4 FT)(EXTEND)LF 20.00047 462 6056CONC BOX CULV (6 FT X 5 FT)(EXTEND)LF 32.00048 462 6062CONC BOX CULV (7 FT X 7 FT)(EXTEND)LF 28.00049 462 6155CONC BOX CULV (3 FT X 2.5 FT)LF 7.00050 464 6003RC PIPE (CL III)(18 IN)LF 2,280.00051 464 6005RC PIPE (CL III)(24 IN)LF 1,137.00052 464 6007RC PIPE (CL III)(30 IN)LF 133.00053 464 6008RC PIPE (CL III)(36 IN)LF 753.00054 464 6009RC PIPE (CL III)(42 IN)LF 32.00055 464 6010RC PIPE (CL III)(48 IN)LF 49.00056 464 6011RC PIPE (CL III)(54 IN)LF 76.00057 464 6014RC PIPE (CL III)(72 IN)LF 33.00058 466 6101HEADWALL (CH - PW - 0) (DIA= 36 IN)EA 2.00059 466 6103HEADWALL (CH - PW - 0) (DIA= 48 IN)EA 1.00060 466 6104HEADWALL (CH - PW - 0) (DIA= 54 IN)EA 2.00061 466 6107HEADWALL (CH - PW - 0) (DIA= 72 IN)EA 2.00062 466 6135HEADWALL (CH - PW - S) (DIA= 42 IN)EA 1.00063 466 6137HEADWALL (CH - PW - S) (DIA= 54 IN)EA 1.00064 466 6193WINGWALL (PW - 2) (HW=4 FT)EA 1.00065 466 6194WINGWALL (PW - 2) (HW=5 FT)EA 3.00066 466 6195WINGWALL (PW - 2) (HW=6 FT)EA 5.00067 466 6196WINGWALL (PW - 2) (HW=7 FT)EA 1.00068 466 6197WINGWALL (PW - 2) (HW=8 FT)EA 1.00069 466 6198WINGWALL (PW - 2) (HW=9 FT)EA 1.00070 467 6014SET (TY I) (36 IN) (3: 1) (C)EA 7.00071 467 6015SET (TY I) (36 IN) (4: 1) (C)EA 16.00072 467 6018SET (TY I) (42 IN) (3: 1) (C)EA 4.00073 467 6025SET (TY I) (54 IN) (3: 1) (C)EA 2.00074 467 6106SET (TY I)(S=3 FT)(HW=3FT)(4:1)(C)EA 4.00075 467 6111SET (TY I)(S=3 FT)(HW= 4 FT)(3:1)(C)EA 1.00076 467 6143SET (TY I)(S= 4 FT)(HW= 4 FT)(3:1) (C)EA 1.00077 467 6148SET (TY I)(S= 4 FT)(HW= 5 FT)(3:1) (C)EA 1.00078 467 6175SET (TY I)(S= 5 FT)(HW= 4 FT)(3:1) (C)EA 1.00079 467 6223SET (TY I)(S= 6 FT)(HW= 6 FT)(3:1) (C)EA 8.00080 467 6244SET (TY I)(S= 7 FT)(HW= 4 FT)(3:1) (C)EA 6.00081 467 6275SET (TY I)(S= 8 FT)(HW= 5 FT)(3:1) (C)EA 4.00082 467 6276SET (TY I)(S= 8 FT)(HW= 5 FT)(4:1) (C)EA 4.00083 467 6303SET (TY I)(S= 9 FT)(HW= 6 FT)(3:1) (C)EA 8.00084 467 6348SET (TY II) (18 IN) (CMP) (6: 1) (P)EA 165.00085 467 6363SET (TY II) (18 IN) (RCP) (6: 1) (P)EA 182.00086 467 6380SET (TY II) (24 IN) (CMP) (6: 1) (P)EA 10.00087 467 6388SET (TY II) (24 IN) (RCP) (3: 1) (C)EA 8.00088 467 6390SET (TY II) (24 IN) (RCP) (4: 1) (C)EA 26.00089 467 6395SET (TY II) (24 IN) (RCP) (6: 1) (P)EA 50.00090 467 6410SET (TY II) (30 IN) (CMP) (6: 1) (P)EA 14.00091 467 6417SET (TY II) (30 IN) (RCP) (3: 1) (C)EA 4.00092 467 6419SET (TY II) (30 IN) (RCP) (4: 1) (C)EA 2.00093 467 6423SET (TY II) (30 IN) (RCP) (6: 1) (P)EA 4.00094 467 6444SET (TY II) (36 IN) (CMP) (6: 1) (P)EA 6.00095 467 6454SET (TY II) (36 IN) (RCP) (6: 1) (P)EA 4.00096 467 6461SET (TY II) (42 IN) (RCP) (3: 1) (C)EA 1.00097 467 6474SET (TY II) (48 IN) (RCP) (3: 1) (C)EA 1.00098 467 6477SET (TY II) (48 IN) (RCP) (4: 1) (C)EA 8.00099 480 6001CLEAN EXIST CULVERTSEA 24.000100 496 6001REMOV STR (BOX CULVERT)EA 1.000101 496 6004REMOV STR (SET)EA 49.000102 496 6005REMOV STR (WINGWALL)EA 24.000103 496 6006REMOV STR (HEADWALL)EA 43.000104 496 6007REMOV STR (PIPE)LF 6,901.000105 500 6001MOBILIZATIONLS 1.000106 502 6001BARRICADES, SIGNS AND TRAFFIC HANDLINGMO 30.000107 506 6002ROCK FILTER DAMS (INSTALL) (TY 2)LF 1,205.000108 506 6011ROCK FILTER DAMS (REMOVE)LF 1,205.000109 506 6020CONSTRUCTION EXITS (INSTALL) (TY 1)SY 420.000110 506 6024CONSTRUCTION EXITS (REMOVE)SY 420.000111 506 6038TEMP SEDMT CONT FENCE (INSTALL)LF 100,050.000112 506 6039TEMP SEDMT CONT FENCE (REMOVE)LF 100,050.000113 529 6008CONC CURB & GUTTER (TY II)LF 100.000114 530 6003INTERSECTIONS (SURF TREAT)SY 2,932.000115 530 6004DRIVEWAYS (CONC)SY 506.000116 530 6005DRIVEWAYS (ACP)SY 8,920.000117 530 6006DRIVEWAYS (SURF TREAT)SY 3,582.000118 540 6001MTL W-BEAM GD FEN (TIM POST)LF 2,950.000119 540 6014SHORT RADIUSLF 50.000120 540 6017MTL BM GD FEN (LONG SPAN SYSTEM)LF 200.000121 540 6026DRIVEWAY TERMINAL ANCHOR SECTION(TY IV)EA 3.000122 544 6001GUARDRAIL END TREATMENT (INSTALL)EA 19.000123 560 6004MAILBOX INSTALL-S (TWG-POST) TY 2EA 74.000124 560 6005MAILBOX INSTALL-D (TWG-POST) TY 2EA 17.000125 560 6006MAILBOX INSTALL-M (TWG-POST) TY 2EA 8.000126 636 6007REPLACE EXISTING ALUMINUM SIGNS(TY A)SF 1.000127 644 6001IN SM RD SN SUP&AM TY10BWG(1)SA(P)EA 75.000128 644 6004IN SM RD SN SUP&AM TY10BWG(1)SA(T)EA 93.000129 644 6007IN SM RD SN SUP&AM TY10BWG(1)SA(U)EA 1.000130 644 6030IN SM RD SN SUP&AM TYS80(1)SA(T)EA 11.000131 644 6045IN SM RD SN SUP&AM TYS80(1)SB(U-1EXT)EA 2.000132 644 6068RELOCATE SM RD SN SUP&AM TY 10BWGEA 1.000133 658 6011INSTL DEL ASSM (D-SW)SZ 2(WC)GND(BI)EA 144.000134 658 6047INSTL OM ASSM (OM-2Y)(WC)GNDEA 82.000135 658 6062INSTL DEL ASSM (D-SW)SZ 1(BRF)GF2(BI)EA 78.000136 662 6004WK ZN PAV MRK NON-REMOV (W)4"(SLD)LF 158,050.000137 662 6034WK ZN PAV MRK NON-REMOV (Y)4"(SLD)LF 158,050.000138 662 6111WK ZN PAV MRK SHT TERM (TAB)TY Y-2EA 6,124.000139 666 6048REFL PAV MRK TY I (W)24"(SLD)(100MIL)LF 172.000140 666 6303RE PM W/RET REQ TY I (W)4"(SLD)(100MIL)LF 156,176.000141 666 6312RE PM W/RET REQ TY I (Y)4"(BRK)(100MIL)LF 10,002.000142 666 6315RE PM W/RET REQ TY I (Y)4"(SLD)(100MIL)LF 93,717.000143 672 6009REFL PAV MRKR TY II-A-AEA 1,711.000144 730 6002FULL - WIDTH MOWINGAC 112.900145 60016002PORTABLE CHANGEABLE MESSAGE SIGNEA 6.000146 61856001TMA (STATIONARY)EA 2.000147 * INCLUDES FORCE ACCOUNT WORK AMOUNTS AS FOLLOWS: CONTRACTOR FORCE ACCOUNT WORK (PART) $1,053,173.10