Tabulation of Bids for Project F 2022(817)
This report will no longer be updated, please access links on the Contract Letting page.
The Electronic State Business Daily (ESBD), the Electronic Bidding System, and the project proposal are the official sources of advertisement and bidding information for the State and Local Lettings. Bidders should bid the project using the information found therein, including any addenda. These sources take precedence over information from other sources, including TxDOT webpages, which are unofficial and intended for informational purposes only.
Text version of this page | |||
County: | HAYS | Let Date: | 08/03/22 |
Type: | INTERSECTION IMPROVEMENT | Seq No: | 3041 |
Time: | 85 WORKING DAYS | Project ID: | F 2022(817) |
Highway: | RM 32 | Contract #: | 08223041 |
Length: | 0.000 | CCSJ: | 0511-03-013 |
Limits: | |||
From: | AT PURGATORY RD | Check: | $19,000 |
To: | . | Misc Cost: |
Estimate | $947,263.80 | % Over/Under | Company |
Bidder 1 | $1,073,849.51 | +13.36% | LONE STAR SITEWORK, LLC |
Bidder 2 | $1,094,331.96 | +15.53% | DAN WILLIAMS COMPANY |
Bidder 3 | $1,133,929.22 | +19.71% | HUNTER INDUSTRIES, LTD. |
Bidder 4 | $1,172,299.78 | +23.76% | AARON CONCRETE CONTRACTORS, L.P. |
Bidder 5 | $1,640,861.45 | +73.22% | ACME BRIDGE COMPANY, INC. |
Item Code | Description | Unit | Quantity | Unit Est. | Bidder | Unit Bid |
1006002 | PREPARING ROW | STA | 17.700 | 3,000.00 | 1 2 3 4 5 | 300.000 3,000.000 2,277.680 1,000.000 6,000.000 |
1056024 | REMOVING STAB BASE AND ASPH PAV (21") | SY | 559.000 | 14.00 | 1 2 3 4 5 | 27.000 15.000 27.900 32.000 27.000 |
1106001 | EXCAVATION (ROADWAY) | CY | 3,105.000 | 12.00 | 1 2 3 4 5 | 19.000 17.000 31.140 28.000 43.000 |
1326003 | EMBANKMENT (FINAL)(ORD COMP)(TY B) | CY | 1,830.000 | 15.00 | 1 2 3 4 5 | 17.500 19.000 31.140 12.000 25.000 |
1606003 | FURNISHING AND PLACING TOPSOIL (4") | SY | 11,401.000 | 2.00 | 1 2 3 4 5 | 5.300 1.250 2.250 3.000 6.900 |
1646035 | DRILL SEEDING (PERM) (RURAL) (CLAY) | SY | 11,401.000 | 0.25 | 1 2 3 4 5 | 0.330 0.270 0.290 0.300 0.290 |
1646071 | BROADCAST SEED (TEMP)(WARM OR COOL) | SY | 11,401.000 | 0.25 | 1 2 3 4 5 | 0.330 0.270 0.230 0.300 0.290 |
1686001 | VEGETATIVE WATERING | MG | 15.000 | 20.00 | 1 2 3 4 5 | 195.000 1.000 75.240 35.000 104.000 |
1696002 | SOIL RETENTION BLANKETS (CL 1) (TY B) | SY | 11,401.000 | 1.30 | 1 2 3 4 5 | 1.400 1.150 1.070 1.300 1.250 |
2476366003 | FL BS (CMP IN PLC)(TY A GR 5)(FNAL POS) | CY | 1,422.400 | 65.00 | 1 2 3 4 5 | 85.000 65.000 58.980 92.000 141.000 |
3106001 | PRIME COAT (MULTI OPTION) | GAL | 741.200 | 5.00 | 1 2 3 4 5 | 6.600 3.250 7.740 3.700 3.450 |
3516004 | FLEXIBLE PAVEMENT STRUCTURE REPAIR(8") | SY | 841.300 | 80.00 | 1 2 3 4 5 | 96.000 72.000 55.320 87.000 82.600 |
4166031 | DRILL SHAFT (TRF SIG POLE) (30 IN) | LF | 22.000 | 450.00 | 1 2 3 4 5 | 480.000 500.000 453.430 495.000 619.000 |
4166032 | DRILL SHAFT (TRF SIG POLE) (36 IN) | LF | 13.000 | 550.00 | 1 2 3 4 5 | 510.000 550.000 481.760 526.000 672.000 |
5006001 | MOBILIZATION | LS | 1.000 | 76,000.00 | 1 2 3 4 5 | 56,400.000 105,000.000 125,339.520 110,000.000 150,000.000 |
5026001008 | BARRICADES, SIGNS AND TRAFFIC HANDLING | MO | 5.000 | 2,000.00 | 1 2 3 4 5 | 1,000.000 13,000.000 2,385.630 1,000.000 25,000.000 |
5066004002 | ROCK FILTER DAMS (INSTALL) (TY 4) | LF | 240.000 | 35.00 | 1 2 3 4 5 | 42.000 35.000 43.050 40.000 37.400 |
5066011002 | ROCK FILTER DAMS (REMOVE) | LF | 240.000 | 15.00 | 1 2 3 4 5 | 32.000 27.000 9.060 30.000 28.800 |
5066038002 | TEMP SEDMT CONT FENCE (INSTALL) | LF | 300.000 | 3.50 | 1 2 3 4 5 | 4.800 4.000 5.100 4.500 4.250 |
5066039002 | TEMP SEDMT CONT FENCE (REMOVE) | LF | 300.000 | 1.00 | 1 2 3 4 5 | 1.200 1.000 1.130 1.100 1.050 |
5066041002 | BIODEG EROSN CONT LOGS (INSTL) (12") | LF | 100.000 | 10.00 | 1 2 3 4 5 | 4.800 4.000 6.800 4.500 4.250 |
5066043002 | BIODEG EROSN CONT LOGS (REMOVE) | LF | 100.000 | 1.00 | 1 2 3 4 5 | 1.200 1.000 2.270 1.100 1.050 |
5306005 | DRIVEWAYS (ACP) | SY | 124.000 | 80.00 | 1 2 3 4 5 | 88.000 100.000 64.800 125.000 137.000 |
6186046 | CONDT (PVC) (SCH 80) (2") | LF | 105.000 | 18.00 | 1 2 3 4 5 | 44.000 37.000 41.940 46.000 25.600 |
6186053 | CONDT (PVC) (SCH 80) (3") | LF | 370.000 | 25.00 | 1 2 3 4 5 | 46.000 38.000 43.080 47.000 35.200 |
6186054 | CONDT (PVC) (SCH 80) (3") (BORE) | LF | 480.000 | 45.00 | 1 2 3 4 5 | 66.000 55.000 62.350 68.000 74.200 |
6206007 | ELEC CONDR (NO.8) BARE | LF | 955.000 | 1.50 | 1 2 3 4 5 | 2.400 2.000 2.270 2.500 2.450 |
6206008 | ELEC CONDR (NO.8) INSULATED | LF | 740.000 | 2.00 | 1 2 3 4 5 | 2.400 2.000 2.270 2.500 2.450 |
6206010 | ELEC CONDR (NO.6) INSULATED | LF | 5.000 | 10.00 | 1 2 3 4 5 | 4.800 4.000 4.530 5.000 3.650 |
6246010 | GROUND BOX TY D (162922)W/APRON | EA | 4.000 | 2,490.00 | 1 2 3 4 5 | 2,280.000 2,200.000 2,153.770 2,350.000 2,030.000 |
6286165 | ELC SRV TY D 120/240 070(NS)AL(E)SP(O) | EA | 1.000 | 6,000.00 | 1 2 3 4 5 | 6,000.000 7,500.000 5,667.820 6,200.000 9,820.000 |
6446001 | IN SM RD SN SUP&AM TY10BWG(1)SA(P) | EA | 1.000 | 750.00 | 1 2 3 4 5 | 1,148.000 1,000.000 927.000 1,100.000 1,020.000 |
6446068 | RELOCATE SM RD SN SUP&AM TY 10BWG | EA | 1.000 | 700.00 | 1 2 3 4 5 | 840.000 725.000 515.000 790.000 747.000 |
6666036007 | REFL PAV MRK TY I (W)8"(SLD)(100MIL) | LF | 620.000 | 1.15 | 1 2 3 4 5 | 3.300 1.060 2.850 3.100 2.950 |
6666048007 | REFL PAV MRK TY I (W)24"(SLD)(100MIL) | LF | 30.000 | 8.50 | 1 2 3 4 5 | 12.000 12.650 10.300 11.200 10.700 |
6666054007 | REFL PAV MRK TY I (W)(ARROW)(100MIL) | EA | 2.000 | 160.00 | 1 2 3 4 5 | 300.000 176.000 257.500 281.000 267.000 |
6666078007 | REFL PAV MRK TY I (W)(WORD)(100MIL) | EA | 2.000 | 170.00 | 1 2 3 4 5 | 312.000 250.000 267.800 292.000 278.000 |
6666224007 | PAVEMENT SEALER 4" | LF | 9,720.000 | 0.25 | 1 2 3 4 5 | 0.310 0.250 0.270 0.300 0.280 |
6666226007 | PAVEMENT SEALER 8" | LF | 620.000 | 0.30 | 1 2 3 4 5 | 0.630 0.430 0.540 0.600 0.560 |
6666230007 | PAVEMENT SEALER 24" | LF | 30.000 | 3.75 | 1 2 3 4 5 | 3.600 4.730 3.090 3.400 3.200 |
6666231007 | PAVEMENT SEALER (ARROW) | EA | 2.000 | 60.00 | 1 2 3 4 5 | 90.000 52.000 77.250 85.000 80.100 |
6666232007 | PAVEMENT SEALER (WORD) | EA | 2.000 | 60.00 | 1 2 3 4 5 | 96.000 77.000 82.400 90.000 85.400 |
6666303007 | RE PM W/RET REQ TY I (W)4"(SLD)(100MIL) | LF | 4,070.000 | 0.50 | 1 2 3 4 5 | 1.000 0.610 0.820 0.900 0.850 |
6666315007 | RE PM W/RET REQ TY I (Y)4"(SLD)(100MIL) | LF | 5,650.000 | 0.50 | 1 2 3 4 5 | 1.000 0.770 0.820 0.900 0.850 |
6726007 | REFL PAV MRKR TY I-C | EA | 32.000 | 5.50 | 1 2 3 4 5 | 7.200 7.000 6.180 6.750 6.400 |
6726009 | REFL PAV MRKR TY II-A-A | EA | 298.000 | 5.00 | 1 2 3 4 5 | 6.300 7.000 5.410 5.900 5.600 |
6776001 | ELIM EXT PAV MRK & MRKS (4") | LF | 7,060.000 | 0.50 | 1 2 3 4 5 | 0.700 0.430 0.620 0.700 0.640 |
6776007 | ELIM EXT PAV MRK & MRKS (24") | LF | 30.000 | 10.00 | 1 2 3 4 5 | 7.200 7.000 6.180 6.750 6.400 |
6786001 | PAV SURF PREP FOR MRK (4") | LF | 800.000 | 0.25 | 1 2 3 4 5 | 0.120 2.000 0.100 0.100 0.110 |
6806001006 | INSTALL HWY TRF SIG (FLASH BEACON) | EA | 1.000 | 6,500.00 | 1 2 3 4 5 | 2,400.000 10,000.000 2,267.130 2,500.000 4,590.000 |
6826003 | VEH SIG SEC (12")LED(YEL) | EA | 10.000 | 330.00 | 1 2 3 4 5 | 360.000 300.000 340.070 372.000 416.000 |
6826005 | VEH SIG SEC (12")LED(RED) | EA | 4.000 | 330.00 | 1 2 3 4 5 | 360.000 300.000 340.070 372.000 416.000 |
6826021 | BACK PLATE (12")(1 SEC) | EA | 14.000 | 75.00 | 1 2 3 4 5 | 100.000 83.000 94.090 103.000 117.000 |
6846031 | TRF SIG CBL (TY A)(14 AWG)(5 CONDR) | LF | 935.000 | 2.50 | 1 2 3 4 5 | 3.600 3.000 3.400 3.700 2.800 |
6866025 | INS TRF SIG PL AM (S)1 ARM(24') | EA | 1.000 | 7,300.00 | 1 2 3 4 5 | 11,400.000 16,000.000 10,768.850 11,700.000 8,170.000 |
6866031 | INS TRF SIG PL AM(S)1 ARM(28')LUM | EA | 1.000 | 11,250.00 | 1 2 3 4 5 | 14,400.000 20,000.000 13,602.760 14,800.000 11,700.000 |
6866039 | INS TRF SIG PL AM(S)1 ARM(36')LUM | EA | 1.000 | 12,500.00 | 1 2 3 4 5 | 15,600.000 23,000.000 14,736.330 16,100.000 14,400.000 |
7306107 | FULL - WIDTH MOWING | CYC | 3.000 | 7,000.00 | 1 2 3 4 5 | 2,000.000 600.000 4,120.000 1,100.000 1,680.000 |
7346002 | LITTER REMOVAL | CYC | 3.000 | 4,000.00 | 1 2 3 4 5 | 1,000.000 300.000 2,357.340 2,100.000 2,920.000 |
7386010 | CLEANING / SWEEPING (SPOT) | MI | 0.350 | 1,450.00 | 1 2 3 4 5 | 3,900.000 350.000 5,400.000 2,000.000 10,275.770 |
7526003 | TREE TRIMMING / BRUSH REMOVAL | MI | 0.350 | 25,000.00 | 1 2 3 4 5 | 6,000.000 80,000.000 10,800.000 59,000.000 101,126.970 |
30766003 | D-GR HMA TY-B PG64-22 (EXEMPT) | TON | 815.300 | 115.00 | 1 2 3 4 5 | 121.600 112.000 134.550 145.000 117.000 |
30766051 | D-GR HMA TY-D PG76-22 (LEVEL-UP) | TON | 310.000 | 140.00 | 1 2 3 4 5 | 179.750 144.000 145.350 171.000 152.000 |
30766072 | D-GR HMA TY-D PG 76-22 (EXEMPT) | TON | 407.700 | 120.00 | 1 2 3 4 5 | 167.000 144.000 145.350 168.000 152.000 |
30816008 | TOM-C PG76-22 SAC-B | TON | 462.700 | 150.00 | 1 2 3 4 5 | 225.000 210.000 177.750 240.000 219.000 |
30846001 | BONDING COURSE | GAL | 667.300 | 5.00 | 1 2 3 4 5 | 5.500 4.250 4.670 4.800 4.550 |
30856001 | UNDERSEAL COURSE | GAL | 1,682.600 | 5.00 | 1 2 3 4 5 | 5.500 4.000 7.740 4.500 4.250 |
60016001 | PORTABLE CHANGEABLE MESSAGE SIGN | DAY | 180.000 | 75.00 | 1 2 3 4 5 | 110.000 120.000 119.140 100.000 209.000 |
61856002002 | TMA (STATIONARY) | DAY | 90.000 | 220.00 | 1 2 3 4 5 | 120.000 175.000 222.710 135.000 267.000 |
61856003002 | TMA (MOBILE OPERATION) | HR | 80.000 | 100.00 | 1 2 3 4 5 | 220.000 55.000 75.350 85.000 645.000 |
72516001 | SUBSURFACE UTIL LOCATE (OUTSIDE RDBED) | EA | 10.000 | 2,250.00 | 1 2 3 4 5 | 600.000 300.000 4,000.000 1,300.000 640.000 |