AVERAGE LOW BID UNIT PRICE - CONSTRUCTION - STATEWIDE

Last Update: Tuesday, October 31, 2017
ITEMS 7060 6005 TO 7095 6001
ItemsItemsBid Code Range
0100 - 0193
0204 - 0292
0305 - 0368
0400 - 0499
0500 - 0560
0610 - 0690
0700 - 0789
0800 - 0800
1000 - 1133
2000 - 2228
3000 - 3061
4000 - 4191
5000 - 5969
6000 - 6834
7000 - 7147
8020 - 8861
9021 - 9063
7000 6002 - 7032 6003
7032 6004 - 7049 6150
7049 6151 - 7058 6050
7058 6051 - 7060 6003
7060 6005 - 7095 6001
7095 6008 - 7122 6010
7122 6011 - 7135 6009
7135 6010 - 7143 6006
7143 6007 - 7147 6003
Item NoDescriptionUnitsAugust 31, 2017Twelve-Month-MovingUsage
QuantityAvg BidQuantityAvg Bid
7060 6005STD PRECAST MANH W/ PRECAST BS 48" DIAEA34.0005,976.4705934.0005,976.470592
7060 6007STND PRECAST MANH W/CIP BS 48" DIAEA7.00013,970.000007.00013,970.000001
7060 6014SPECIAL BYPASS PUMPING MANHOLEEA1.00034,200.000001.00034,200.000001
7060 6017EXTRA DEPTH OF MANHOLE 48"LF183.000547.81421183.000547.814212
7060 6018EXTRA DEPTH OF MANHOLE 60"LF29.400825.0000029.400825.000001
7060 6019MINOR MANH HEIGHT ADJUSTMENT 48" DIAEA28.0002,090.0000030.0001,998.000002
7060 6024PIPE 8" DIA PVC SDR26 TYPELF6,353.000123.000006,353.000123.000001
7060 6028REMOVE EXISTING MANHOLEEA22.0005,331.8181822.0005,331.818182
7060 6032PIPE 15" DIA SDR-26 TY (ALL DEPTHS)LF300.000400.00000300.000400.000001
7060 6033ABANDON 15" WW LINELF300.00036.00000300.00036.000001
7060 6034ENCASEMENT PIPE 30" DIA, TYPE STEELLF270.000250.00000270.000250.000001
7060 6035PIPE 15" DI PVC SDR26 TYPELF640.000168.00000640.000168.000001
7060 60368" PLUG ON STUB-OUTEA17.0001,430.0000017.0001,430.000001
7060 6038PRCST MANHW/DRP INLT ON PRCST BS 48"DIEA5.00014,850.000005.00014,850.000001
7060 6039STD PRECAST MANH W/PRECAST BS 60"DIAEA3.0009,680.000003.0009,680.000001
7060 6040CONNECT TO EXISTING PIPE 12" DIAEA1.0003,300.000001.0003,300.000001
7062 6001SWING BRIDGE CONTROL HOUSELS  1.00065,000.000001
7063 6001ELECTRIC UTILITY FEEDEREA  1.00016,056.000001
7063 6002GENERAL ELECTRICAL MATERIALS & CONTROLLS  1.000246,171.000001
7063 6003BRIDGE CONTROL SYSTEM AND MCCLS  1.000160,282.000001
7063 6004BRIDGE CCTVLS  1.00047,087.000001
7063 6005OPERATOR HOUSE ELECTRICAL SYSTEMSLS  1.000243,028.000001
7063 6006SWING SPAN DRIVE MOTOREA  1.00020,673.000001
7063 6007THRUSTER BRAKEEA  1.00025,718.000001
7063 6008WEDGE DRIVE MOTOREA  4.0009,534.000001
7063 6009SPAN SEATED LIMIT SWITCHEA  2.0004,927.000001
7063 6010SPAN POSITION LIMIT SWITCHESEA  4.00012,524.000001
7063 6011WEDGE ROTARY CAM LIMIT SWITCHESEA  4.0007,373.000001
7063 6012WEDGE PROXIMITY LIMIT SWITCHEA  8.000778.000001
7063 6013MOTOR DISCONNECT SWITCHESEA  6.0004,800.000001
7063 6014TRAFFIC GATE ASSEMBLIESEA  2.00025,730.000001
7063 6015RESISTANCE BARRIERSEA  2.00052,055.000001
7063 6016NAVIGATION LIGHTINGLS  1.00034,620.000001
7063 6017FIXED MOVEABLE STR CABLE TRANS SYSTLS  1.00016,056.000001
7064 6001FUNCTIONAL TESTINGLS  1.00044,200.000001
7064 6002CENTER BEARINGLS  1.000100,000.000001
7064 6003SPAN DRIVE AND TRACKLS  1.000250,000.000001
7064 6004BALANCE WHEELSLS  1.00060,000.000001
7064 6005END WEDGESLS  1.000670,000.000001
7064 6006CENTER PIER LIVE LOAD SUPPORTSLS  1.00050,000.000001
7064 6007OPEN AND CLOSED BUMPERSLS  1.00020,000.000001
7064 6008SPAN BALANCINGLS  1.00050,000.000001
7065 6001FENDER AND DOLPHIN INSTALLATIONLS  1.000970,000.000001
7066 6001SWING BRIDGE REHABILITATIONLS  1.0002,000,000.000001
7082 6001SUBMARINE CABLE REPLACEMENTLS  1.000274,000.000001
7087 6001TRENCH EXCAVATION PROTECTIONLF  1,693.0002.884232
7087 6002PIPE WATER MAIN (PVC)(6")LF  72.000100.000001
7087 6003PIPE WATER MAIN (PVC)(16")LF  38.000150.000001
7087 6011DUCTILE IRON FITTINGSTON  4.8807,500.000001
7087 6012TIE-IN (COMP)(6")EA  4.0001,000.000001
7087 6013TIE-IN (COMP)(16")EA  2.0003,500.000001
7087 6014HYDROSTATIC PRESSURE TESTEA  9.0001,675.000001
7087 6015TEMPORARY BLOW-OFF (COMP)(2")EA  16.0001,000.000001
7087 6016AUTOMATIC AIR RELEASE VALVE (COMP)(1")EA  4.0003,500.000001
7087 6019CASING FOR OPEN CUT TRENCH (30")LF  22.000225.000001
7087 6025CARRIER PIPE FOR BORING (16")LF  22.0001,065.000001
7087 6027ADJUST EXISTING VALVE BOXEA  51.000740.784312
7087 6028CONCRETE ENCASEMENT AND SADDLESCY  1,587.000265.519852
7087 6030ADJUST FIRE HYDRANTEA  3.0002,300.000002
7087 6046FIRE HYDRANT WITH 6IN VALVE AND BOXEA  13.0004,860.000001
7087 6048TIE IN (COMP)(12")EA  8.0001,206.000001
7087 6050FLOWABLE BACKFILLCY  3,120.00090.000001
7087 6051SERV LINE BRK/LEAK REPAIR(ALL SIZES)EA  12.0002,250.000002
7087 6052WATER MAIN BREAK / LEAK REPAIR (20")EA  2.00010,500.000001
7087 6054RELOCATE EXIST METER AND NEW METER BOXEA  7.000850.000001
7087 6055PIPE WATER MAIN (PVC) (8")LF  42.000100.000001
7087 6056PIPE WATER MAIN (PVC) (12")LF  187.000125.000001
7087 6057CASING FOR OPEN CUT TRENCH (24")LF  138.000163.000001
7087 6058CARRIER PIPE FOR OPEN CUT TRENCH (12")LF  138.000122.000001
7087 6059GATE VALVE AND BOX (COMP) (8")EA  2.0001,900.000001
7087 6060CUT - IN TEE (COMP) (12"X8")EA  2.0002,200.000001
7087 6061CUT - IN GATE VALVE AND BOX (COMP)(12"EA  4.0003,450.000001
7087 6062TIE - IN (COMP) (8")EA  2.0001,100.000001
7087 6063WATER MAIN BREAK/LEAK REPAIR(ALL SIZESEA  10.0005,000.000001
7087 6064RELAY SHORT SERVICE (ALL SIZES)EA  2.0001,535.000001
7087 6065RELAY SHORT SERVICE (3/4")EA  1.0002,300.000001
7087 6066RELAY LONG SERVICE (2")EA  1.0003,500.000001
7087 6067WATER MAIN BREAK / LEAK REPAIR (6")EA  2.0004,500.000001
7088 6003SANITARY SEWER (ADJUST MANHOLE)EA  2.0001,100.000001
7090 6001SANITARY SEWER (ADJUST MANHOLE)EA  3.000683.333332
7090 6002SANITARY SEWER (BY-PASS PUMPING)LS  1.00015,000.000001
7091 6001ADJUST EXISTING VALVE BOXEA  13.000565.384622
7091 6002ADJUST EXISTING FIRE HYDRANT (COMPLETEEA  2.0001,250.000001
7091 6003ADJUST EXISTING METER AND NEW METER BOEA  10.000300.000001
7092 6002GROUT ABANDONMENT GAS MAIN (12" STEEL)LF  363.00060.000001
7092 6003GROUT ABANDONMENT GAS MAIN (6 )LF  4,890.00040.000001
7092 6004GROUT ABANDONMENT GAS MAIN (8 )LF  877.00038.155072
7094 600148" PRECAST CONCRETE MANHOLEEA  15.0004,600.000001
7094 6002RECONNECT EXISTING SEWER MAINSEA  12.000605.000001
7094 60038" SDR-35 PVC GRAVITY SEWER LINESLF  1,069.00050.000001
7094 600410" SDR-35 PVC GRAVITY SEWER LINESLF  110.00065.000001
7094 6007ENCAS FOR 8" SWR LN (BORE OR OPN-CUT)LF  425.000250.000001
7094 6008ENCAS FOR 10" SWR LN (BORE OR OPN-CUT)LF  95.000265.000001
7094 6010REMOVE EXIST SEWER LINE (2"-10")LF  640.00012.000001
7094 6011TRENCH SAFETY (DEPTHS GRTER THAN 5 FT)LF  1,709.0001.100001
7094 6012TEMPORARY PAVEMENT REPLACEMENTLF  1,709.00033.000001
7094 60138" GRAVITY SWR LN INSTALL BY BORE(HDPELF  148.000118.000001
7094 6014ABANDON EXIST SWR LN/PRESSR GRT(2"-12"LF  687.00027.500001
7094 6015SEWER SERVICE RECONNECTSEA  4.000913.000001
7095 6001ABANDON EXIST WTR LN/PRSSR GRT (2"-12"LF  570.00027.500001